Logged in as:

Show all filters

Hide all filters

Gaffelkabelskor (rullpress)


NEMIQ
Reel/roll packaging:
Yes
Max. current (Imax):
16 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
None
Colour insulation:
Other
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-110 °C
Material:
Copper
Neck type:
Open barrel crimp

RK TM - Cable


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-30-70 °C
Core colour:
Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B3
Min. permitted bending radius, stationary application/permanent installation:
38.4-73.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKUB Förtent Multi conductor - Spools


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Tinned
Packaging:
Reel B4
Min. permitted bending radius, stationary application/permanent installation:
18.8-36 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKUB Förtent Single conductor - Spools


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Operating temperature:
-25-70 °C
Core colour:
Red, Black
Conductor surface:
Tinned
Packaging:
Reel B3, Reel B4
Min. permitted bending radius, stationary application/permanent installation:
10-16.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

SYYB


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyurethane (PUR)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyurethane (PUR)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-50-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
70.4-104 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKKB Single conductor


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Red/black, Black/Black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Reel B3
Min. permitted bending radius, stationary application/permanent installation:
10.6-15 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
55-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

H01N2-D FT - Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
66-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKXB - DRUM


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Drum, Reel B5
Min. permitted bending radius, stationary application/permanent installation:
25.6-30.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKUB Multi conductor - Mini-spools


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black, Grey/Grey, Black/Black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Reel B1
Min. permitted bending radius, stationary application/permanent installation:
18.8-26 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum 500 m


NEMIQ
Number of cores:
3-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
59.5-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKKB - Drum


NEMIQ
Number of cores:
2-16 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Grey
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
18.4-55.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKUB Tinned Multi-conductor - Drum


NEMIQ
Single insulated/Double insulated:
Single insulated
Yes

R2G4 - 400 m spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-100 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
100 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Modularkabel


NEMIQ
Number of cores:
4 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
13.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-Y (LiYY) - Trumma 500 m, partvinnade


NEMIQ
Number of cores:
4-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
25.5-62 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RKUB Multi conductor - Drum


NEMIQ
Number of cores:
2 .
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Max. conductor temperature:
70 °C
Min. permitted bending radius, stationary application/permanent installation:
15.2-18.8 mm
Yes

Ratchet Cable Cutters - NRCC


NEMIQ
Grip design:
1-component
With impact protection:
No
Replaceable cutting head:
Yes
Cutting jaws exchangeable:
Yes
With strip function:
No
Insulated:
Yes
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
No
Construction/operation:
Ratchet model mechanical
Isolation protection 1000 V:
No
VDE tested:
No

NELCOFLEX-CY (EMC) - 100m


NEMIQ
Number of cores:
3-25 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Transparent
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
31.6-66.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Ringkabelskor (svetsad)


NEMIQ
Reel/roll packaging:
No
Max. current (Imax):
19-160 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
None
Colour insulation:
Other
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Nickel-plated
Operating temperature:
-55-400 °C
Material:
Nickel
Neck type:
Welded
UL-File No.:
E44245
Yes
Yes

Gaffelkabelskor (Rullpress)


NEMIQ JST
Reel/roll packaging:
Yes
Max. current (Imax):
19 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
None
Colour insulation:
Other
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-110 °C
Material:
Brass
Neck type:
Open barrel crimp
UL-File No.:
E42024
Yes
Yes

Heat-shrink insulated Ring terminals DS-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-125 °C
Material:
Copper
Voltage max:
600V
Yes
Yes

Heat-shrink insulated Spade terminals DS-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-125 °C
Material:
Copper
Voltage max:
600V
Yes
Yes

Gaffelkabelskor (rullpress)


NEMIQ
Reel/roll packaging:
No
Max. current (Imax):
16 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
None
Colour insulation:
Other
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-110 °C
Material:
Brass
Neck type:
Open barrel crimp
Yes
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.