Refined by
Hide irrelevant options
Nominal cross section conductor
Number of cores
Colour outer sheath
Screen
Material outer sheath
Protective conductor
Outer diameter approx.
Min. permitted bending radius, stationary application/permanent installation
Armouring/reinforcement
Show all filters
Hide all filters
- Total: 2
RADOX 3 GKW/S EMC
3 GKW/S EMC_vp
Halogenfri styrkabel för skyddad fast förläggning i tågapplikationer. Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen.
Användningsområden är styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Tålig mot hög mekanisk belastning, olja och bränsle.
- Number of cores:
- 3-8 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes, No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding, None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 48.6-240.24 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3 GKW, multi conductor
80030
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX GKW P / GKW HP (polyolefin copolymer)
Conductor color: White, numbered. Transparent plastic foil
Conductor insulation outer sheath: RADOX GKW S (polyolefin copolymer)
Sheath color: Black
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals, flame resistance
BS 6853
DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-8 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin, None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 44.7-106.08 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 2