Refined by
Hide irrelevant options
Product Category
Product Group
Single insulated/Double insulated
Colour
Nominal cross section conductor
Halogen free
Packaging
Material insulation
Conductor Surface
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Core identification
Flame retardant
Conductor category
Low smoke (according to BS EN 61034-2)
Reaction-to-fire class according to EN 13501-6
AWG size
Show all filters
Hide all filters
Texiline
Flexible connection cable for internal cabling in lamps, heating devices, electrical machines, control and control cabinets and in the construction industry. Ideal for installation inside pipes and for surface installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical impact. The coupling wire is difficult to ignite, in case of fire develops minimally with smoke and no corrosive gases are emitted.
Conductor: Tinned copper
DNV-approved from 1.0mm²
Conductor temperature: + 90ºC
Voltage Rating U0 / U (Um): 0.6 / 1 (1.2) kV
Standards:
Conductor: IEC 60228.5
Construction: IEC 60092-350IEC 60092-353IEC 60092-360
Halogen free: IEC 60754-1
Fire resistant: IEC 60332-1
Smoke density: IEC 61034-1 / 2
Approved by: DNV
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Grey, Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 90 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Blue, Brown, Grey, Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 6-14.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Spool
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Structure
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical dataRating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF) Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 58.2-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Drum
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Packaging: Drum
Structure:
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical data
Rating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF)Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 66-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
UL 1015
UL/CSA-godkänd PVC-kopplingskabel för intern kabeldragning av kopplingsskåp, medicinsk utrustning, elektroniska moduler och styrsystem samt för installation i ledningar och rör
i maskiner och som anslutningstråd för transformatorer och motorer.
Max 600 V AC.
Uppbyggnad Ledare: Förtent mångtrådig koppar
Ledarisolation: PVC
Ledarfärg: Enligt tabell
Ledar resistance enligt IEC 60228
MIn. Böjradie fast förlagd 10 x d
Min. Böjradie rörligt förlagd15 x d
Driftspänning: 600 V AC
Provspänning: 3kV
Temp. Område :
Ledartemperatur vid kontinuerlig drift -40ºC till +105ºC.
Lägsta monteringstemperatur -10ºC
Godkännande:
UL Subject 758 AWM, Style 1015. Isolation: UL 1581
UL: VW-1 CSA: FT1
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -25-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 10.2-19.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
Kopplingskabel för solceller H1Z2Z2-K - Ring
H1Z272-K solar cell connection cable offers an optimal solution when it comes to connecting solar panels to each other or with junction boxes and frequency converters. The cable is very resistant to mechanical impact. Good properties in terms of temperature range, chemical resistance, UV resistance and short-circuit resistance. The cable is halogen free.
Construction:
Conductor: Tinned copper according to IEC 60228 class 5
Conductor insulation:
Inner sheath: POLYOLEFIN
Outer sheath: POLYOLEFIN
Coat color: See product facts
Technical data:
Minimum bending radius:
Variable = D < 8 mm² x cable diameter Ø
Fixed = D > 8 mm3 x cable diameter Ø
Temperature range: -40ºC to + 110ºC
Rated voltage: Uo / U AC: 1000V, DC: 1500V
Test voltage: 6500VAC
Approvals:
EN 50575: 2014
EN 50575 / A1: 2016 CE EN 50618 CPR Eca
Kopplingskabel för solceller H1Z2Z2-K - Trumma
H1Z272-K solar cell connection cable offers an optimal solution when it comes to connecting solar panels to each other or with junction boxes and frequency converters. The cable is very resistant to mechanical impact. Good properties in terms of temperature range, chemical resistance, UV resistance and short-circuit resistance. The cable is halogen free.
Construction:
Conductor: Tinned copper according to IEC 60228 class 5
Conductor insulation:
Inner sheath: POLYOLEFIN
Outer sheath: POLYOLEFIN
Coat color: See product facts
Technical data:
Minimum bending radius:
Variable = D < 8 mm² x cable diameter Ø
Fixed = D > 8 mm3 x cable diameter Ø
Temperature range: -40ºC to + 110ºC
Rated voltage: Uo / U AC: 1000V, DC: 1500V
Test voltage: 6500VAC
Approvals:
EN 50575: 2014
EN 50575 / A1: 2016 CE EN 50618 CPR Eca
RQ (H05Z-K, H07Z-K) - Box
Used as connectors line and installation line.
Structure
Conductors: Bare stranded copper
Conductor Insulation: Halogen free polymer blends
Core identification: The table below
Technical data:
Rated voltage:
H05Z-K 0.5-1.0 mm²: 300/500
VH07Z-K 1.5-120 mm²: 450/750 V
Test voltage:
H05Z-K 0.5-1.0 mm²: 2000
VH07Z-K 1.5-120 mm²: 2500 V
Max operating temperature +70ºC (+158ºF) H05Z-K
Max operating temperature +90ºC (+194ºF) H07Z-K
Can handle a short operating temperature of +250ºC (+482ºF)
Minimum bend radius: 12 x cable diameter
Packaging
Box: RQ 0.5-6.0 mm²
- Number of cores:
- 1 .
- Material core insulation:
- Other
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -15-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70-90 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300-600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
- Material insulation:
- Polymen
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
- Conductor surface:
- Bare, Tinned
- Halogen free:
- Yes
- Packaging:
- Carton (box)
- Min. permitted bending radius, stationary application/permanent installation:
- 10.4-19 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
TX UL 3607
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin.
Idealisk för installation inuti rör samt för utanpåliggande installation. Mycket goda elektriska och mekaniska egenskaper.
Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan.
Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
Halogenfri.
Uppbyggnad
Ledare: Förtent flertrådig koppar
Ledarisolation: XHFFR
Mantelfärg: Se produktdata nedan
Tekniska data:
Driftspänning: 600 V
Temp.område: -40ºC till +105ºC
Godkännanden, flambeständighet
UL file E164256, AWM IEC 60751-1 IEC 60754-2
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- XLPE
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Drum, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 7.2-41.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIF
Connecting cable with insulation of silicone rubber. The wire is particularly suitable as internal wiring in light fixtures, furnaces, heaters and appliances, where the wire is continuously exposed to high temperatures. The wire is halogenfree.
Packaging: Coil
Structure:
Conductors: Stranded tinned copper
Conductor Insulation: Silicone rubber
Core identification: The table below
Technical data:
Rated voltage: 300/500V
Test voltage: 2000V
Temperature range: -50ºC to +180ºC (-58ºF to 356ºF)
Minimum bend radius:
Moving: 12 x cable diameter
Fixed: 6 x cable diameter
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -60-185 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 185 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Silicone
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Ring
- Min. permitted bending radius, stationary application/permanent installation:
- 7.5-19.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
TX UL 3746
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin.
Idealisk för installation inuti rör samt för utanpåliggande installation. Mycket goda elektriska och mekaniska egenskaper.
Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan.
Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
Halogenfri.
Uppbyggnad
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation: XHFFR
Mantelfärg: Se produktdata nedan
Tekniska data:
Driftspänning: 300 V
Temp.område: -40ºC till +105ºC
Godkännanden, flambeständighet
IEC60754-1
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- XLPE
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 4.05-6.42 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 155 - Spools
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Spool HS150, Spool HS151, Spool HS400, Spool HS200, Spool HS600
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-37.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
EN-Cable, Single core conductor
Halogenfria, elektronstråle-tvärlänkade kablar med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyller kraven för EN 50264- 3- 2,EN 50306-4.
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift.
Riktlinjer för val och installation beskrivs i standarderna:
EN 50355 och EN 50343.
RADOX EN 50264- 3- 2 ,EN 50306-4600V MM Flerledarkablar med reducerade väggmått.
Nominell spänning: 600 / 1000 V AC.
Risknivå: MM (extra låg temperatur, extra olja och extra bränslebeständig).
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour, None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- White
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- White
- Material insulation:
- Polyolefin (POE)
- Core colour:
- White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.26-8.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Spool
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS150, Spool HS151, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-20.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX UL3289
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Drum, Spool HS151, Spool HS400, CK, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 7.2-30.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes, No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Drum
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green/yellow, Red
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Drum
- Min. permitted bending radius, stationary application/permanent installation:
- 25.5-73.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Conipack
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
Structure:
Conductor: Tinned stranded copper acc. to IEC 60228 class 5
Conductor insulation: RADOX 125 (polyolefin)
Sheath Colour: See product data below
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Grey, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Grey, Yellow, Brown, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Green/yellow, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- CK
- Min. permitted bending radius, stationary application/permanent installation:
- 6.75 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTOL 155S FLR-A
Vehicle cable that has (FHLR91X According to DIN76722) excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure, temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in hybrid and electric vehicles, trucks, among others.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155S (polyolefin)
Coat color: See product data.
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage AC: <
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 3 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Green, Orange, Red, Black, White
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -40-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes, No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated, Double insulated
- Colour:
- Black, Green, Orange, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Green, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes, No
- Packaging:
- CK2
- Min. permitted bending radius, stationary application/permanent installation:
- 4.5-6.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 155 - Conipack
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Black
- Flame retardant:
- No
- Conductor material:
- Copper
- Twisted cores:
- No
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Brown, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Black
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- CK
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 9 GKW-AX/S 3600/6000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Skärm: Förtent kopparfläta. Täckningsgrad c:a 85%.
Mantelfärg: Svart
Tekniska data:
Driftspänning: 3.6/6.0 kV AC, 4.5/9.0 kV DC
Provspänning: 12 kV (50 Hz, 15 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet:
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3600 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Drum
- Low smoke (according to EN 61034-2):
- Yes
RADOX 4 GKW-AX 1800/3000 V M J - Single conductor
Halogenfri dubbelisolerad flexibel kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 2 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Colour:
- Black
- Halogen free:
- Yes
RADOX 4 GKW-AX/S 1800/3000 V - Single core conductor
Halogenfri skärmad dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Skärm: Förtent kopparfläta. Täckningsgrad c:a 85%.
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Drum
- Low smoke (according to EN 61034-2):
- Yes
RADOX 9 GKW-AX 3600/6000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 3.6/6.0 kV AC, 4.5/9.0 kV DC
Provspänning: 12 kV (50 Hz, 15 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet:
BS 6853
DIN 5510
NF F16-101
BS 4066-3,
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1,
EN 50265-2-1 IEC 60332-3-24,
EN 50266-2-4 IEC 60754-1,
EN 50267-2-1 IEC 60754-2,
EN 50267-2-3 IEC 61034-2,
EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3600 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS401
- Low smoke (according to EN 61034-2):
- Yes
RADOX GKW-LW - Single core conductor
Halogenfri dubbel isolerad, tunn väggisolering, polymer med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyller kraven för EN 50306-2.
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift.
Riktlinjer för val och installation beskrivs i standarderna:
EN 50355 och EN 50343.
Nominell spänning: 600 / 1000 V AC.
- Colour outer sheath:
- White
- Colour:
- White
- Halogen free:
- Yes
- Packaging:
- Spool HS200
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No