Refined by
Hide irrelevant options
Product Category
Product Group
Single insulated/Double insulated
Colour
Nominal cross section conductor
Halogen free
Max. conductor temperature
Packaging
Material insulation
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Flame retardant
Conductor category
Outer diameter approx.
Low smoke (according to BS EN 61034-2)
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Nominal voltage
Trademark
Show all filters
Hide all filters
- Total: 7
Texiline
Texiline_VP
Flexible connection cable for internal cabling in lamps, heating devices, electrical machines, control and control cabinets and in the construction industry. Ideal for installation inside pipes and for surface installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical impact. The coupling wire is difficult to ignite, in case of fire develops minimally with smoke and no corrosive gases are emitted.
Conductor: Tinned copper
DNV-approved from 1.0mm²
Conductor temperature: + 90ºC
Voltage Rating U0 / U (Um): 0.6 / 1 (1.2) kV
Standards:
Conductor: IEC 60228.5
Construction: IEC 60092-350IEC 60092-353IEC 60092-360
Halogen free: IEC 60754-1
Fire resistant: IEC 60332-1
Smoke density: IEC 61034-1 / 2
Approved by: DNV
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Grey, Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 90 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Blue, Brown, Grey, Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 6-14.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Spool
H01N2_D_FT_Trumma 25m_vp
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Structure
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical dataRating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF) Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 58.2-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKUB Förtent Single conductor - Mini-spools
RKUB_Förtent_enkelledare_minibobiner_vp
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B1: 90mm x 11mm x 42mm
Spool B2: 130mm x 56mm x 59mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Red
- Operating temperature:
- -25-70 °C
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Packaging:
- Reel B1
- Min. permitted bending radius, stationary application/permanent installation:
- 10-24 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Drum
H01N2_D_FT_Trumma_500m_vp
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Packaging: Drum
Structure:
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical data
Rating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF)Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 66-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKUB Förtent Single conductor - Spools
RKUB Förtent Enkelledare
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Red
- Operating temperature:
- -25-70 °C
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Packaging:
- Reel B3, Reel B4
- Min. permitted bending radius, stationary application/permanent installation:
- 10-16.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIF
73901
Connecting cable with insulation of silicone rubber. The wire is particularly suitable as internal wiring in light fixtures, furnaces, heaters and appliances, where the wire is continuously exposed to high temperatures. The wire is halogenfree.
Packaging: Coil
Structure:
Conductors: Stranded tinned copper
Conductor Insulation: Silicone rubber
Core identification: The table below
Technical data:
Rated voltage: 300/500V
Test voltage: 2000V
Temperature range: -50ºC to +180ºC (-58ºF to 356ºF)
Minimum bend radius:
Moving: 12 x cable diameter
Fixed: 6 x cable diameter
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -60-185 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 185 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Silicone
- Operating temperature:
- -40-185 °C
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Ring
- Min. permitted bending radius, stationary application/permanent installation:
- 7.5-19.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTOL 155S FLR-A
RADOX AUTOL
Vehicle cable that has (FHLR91X According to DIN76722) excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure, temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in hybrid and electric vehicles, trucks, among others.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155S (polyolefin)
Coat color: See product data.
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage AC: <
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 3 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Green, Orange, Red, Black, White
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -40-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes, No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated, Double insulated
- Colour:
- Black, Green, Orange, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-155 °C
- Core colour:
- Blue, Brown, Green, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes, No
- Packaging:
- CK2
- Min. permitted bending radius, stationary application/permanent installation:
- 4.5-6.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 7