Refined by
Hide irrelevant options
Product Group
Nominal cross section conductor
Number of cores
Protective conductor
Outer diameter approx.
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Show all filters
Hide all filters
- Total: 1
RDO (H05RN-F)
RDO_kabel_vp
H05RN-FConnection cable of rubber for use in power tools and light engineering equipment, which means high mechanical stresses occur, in both dry and humid rooms, even outdoors.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H05RN-F: 300/500V
Test voltage: H05RN-F: 2000V
Insulation Resistance > 1 Gohma x cm
Core identification H05RN-F:
2-conductor: blue, brown
3conductor: Green / yellow, blue, brown
4-conductor Green / yellow, brown, black, gray
5-conductor Green / yellow, blue, brown, black, gray
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-3 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -25-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- EPDM
- Operating temperature:
- -25-60 °C
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 33-41 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 1