0

Logged in as:

Show all filters

Hide all filters

  • Total: 8

RKUB Förtent Multi conductor - Coil


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Tinned
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
22.8-36 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RKUB Förtent Multi conductor - Spools


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Tinned
Packaging:
Reel B4, Reel B5
Min. permitted bending radius, stationary application/permanent installation:
18.8-36 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RKUB Förtent Multi conductor - Mini-spools


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Tinned
Packaging:
Reel B1, Reel B4
Min. permitted bending radius, stationary application/permanent installation:
22.8-36 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RKUB Tinned Multi-conductor - Drum


NEMIQ
Single insulated/Double insulated:
Single insulated
Yes
Yes

RADOX AUTO B - Multi conductor Tinned


Huber+Suhner
Number of cores:
2 .
Colour outer sheath:
Orange
Single insulated/Double insulated:
Double insulated
Colour:
Orange
Halogen free:
Yes
Yes

RADOX MARIN MFH-S B


Huber+Suhner
Number of cores:
3 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
120 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-120 °C
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
17.25 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RADOX AUTO B - Multi conductor red Tinned


Huber+Suhner
Number of cores:
3 .
Colour outer sheath:
Orange
Nominal voltage:
1000 V
Single insulated/Double insulated:
Double insulated
Colour:
Orange
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-150 °C
Conductor surface:
Tinned
Halogen free:
Yes
Yes

RADOX MARIN MFH-S B, Twisted pair


Huber+Suhner
Number of cores:
8-28 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyolefin
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-40-120 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
120 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Core colour:
Several
Conductor surface:
Tinned
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
31.5-42.3 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
  • Total: 8