Refined by
Hide irrelevant options
Product Category
Product Group
Single insulated/Double insulated
Colour
Nominal cross section conductor
Max. conductor temperature
Packaging
Number of cores
Core insulation material
Halogen free (according to EN 60754-1/2)
Colour outer sheath
Screen
Material outer sheath
Outer diameter approx.
Low smoke (according to BS EN 61034-2)
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Armouring/reinforcement
Twisted cores
Nominal voltage
Trademark
Show all filters
Hide all filters
- Total: 7
RKUB Förtent Multi conductor - Mini-spools
RKUB_förtent_flerledare_minibobiner_vp
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B1: 90mm x 11mm x 42mm
Spool B2: 130mm x 56mm x 59mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Red/black
- Operating temperature:
- -25-70 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Packaging:
- Reel B1, Reel B4
- Min. permitted bending radius, stationary application/permanent installation:
- 22.8-36 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKUB Tinned Multi-conductor - Drum
RKUB_Förtent_flerledare_trumma_vp
Connection cable for car and boat applications.
The cable comes on reel of 4 m, 5 m, 8 m or 10 m. See table below.
Packaging (OD x Hub x Width):
Spool B4: 160mm x 56mm x 90mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
RKUB Förtent Multi conductor - Spools
RKUB Förtent Flerledare
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B4: 160mm x 56mm x 90mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Red/black
- Operating temperature:
- -25-70 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Packaging:
- Reel B4
- Min. permitted bending radius, stationary application/permanent installation:
- 18.8-36 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTO B - Multi conductor Tinned
80045
Shielded power cable for use in hybrid and electric vehicles (FHLR91XC13X & FHLR4GC13X)
Excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in trucks, among other things.
CAUTION: Special care must be taken for cables used with voltages above 60VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155 (polyolefin)
Coat color: Orange
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage: 50HZ, 1MIN 3500 kV AC
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 4 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 2 .
- Colour outer sheath:
- Orange
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Orange
- Halogen free:
- Yes
RADOX AUTO B - Multi conductor red Tinned
Raox_auto_b_p_flerledare_vp
Shielded power cable for use in hybrid and electric vehicles (FHLR91XC13X & FHLR4GC13X)
Excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in trucks, among other things.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Annealed copper according to ISO C flexible 6
Conductor insulation: 155 (polyolefin)
Coat color: Orange
Technical data:
Operating voltage: 1000VAC 1500VDC
Test voltage: 50HZ, 1MIN 3500 kV AC
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 4x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 3 .
- Colour outer sheath:
- Orange
- Nominal voltage:
- 1000 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Orange
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-150 °C
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX MARIN MFH-S B, Twisted pair
Radox_Marin_MFH_S_B_Partvinnad
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 8-28 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 31.5-42.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX MARIN MFH-S B
80046
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 3 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 17.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 7