Refined by
Hide irrelevant options
Nominal cross section conductor
Core colour
Colour outer sheath
Outer diameter approx.
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Show all filters
Hide all filters
- Total: 3
R3 - Box
R3-kabel_VP
Flame retardant thermoplastic cable XHFFR, suitable for vehicles use on low voltage applications and systems, without direct contact of heat sources on the cable.
Suitable for applications inside the engine compartment.
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Technical data
100V
Temp. range: -40º C to + 125º C
Approvals:
ISO 6722 class C
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Pink, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Pink, Black and white, Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 5.85-6.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
R3 2-colors - Spool
R3-kabel_2-färgade_bobin_vp
Flame retardant thermoplastic cable XHFFR, suitable for vehicles use on low voltage applications and systems, without direct contact of heat sources on the cable.
Suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Technical data
100V
Temp. range: -40º C to + 125º C
Approvals:
ISO 6722 class C
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 4.8-9.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
R3 1-color - Spool
R3-kabel_1-färgade_bobin_vp
Flame retardant thermoplastic cable XHFFR, suitable for vehicles use on low voltage applications and systems, without direct contact of heat sources on the cable.
Suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Technical data
100V
Temp. range: -40º C to + 125º C
Approvals:
ISO 6722 class C
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Purple, Pink, Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Pink, Red, Black, White, Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 3.6-34.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 3