0

Logged in as:

Show all filters

Hide all filters

Welding Cable - Double Insulated, ring


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Yellow, Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Yellow, Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Welding Cable - Double Insulated, spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Yellow, Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Yellow, Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Welding Cable - Double Insulated, drum


Number of cores:
1 .
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Nominal voltage:
600 V
Operating temperature:
-40-80 °C
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
90 mm

Welding Cable - H01N2-D FT, spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
58.2-115.2 mm
UL-File No.:
Not Applicable
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Welding Cable - H01N2-D FT, drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
66-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

ADR-kabel


NEMIQ
Number of cores:
2-15 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyurethane (PUR)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
No
Permitted cable outer temperature after assembling without vibration:
-30-85 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
85 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Operating temperature:
-40-80 °C
Core colour:
Several
Conductor surface:
Bare
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
54.08-170.56 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RK (H05V-K, H07V-K)


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300-600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H05V-K (RK 0.5-1.0mm2), H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring, Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
12.4-18.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
25.6-60.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

SKUB Tvillingkabel


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-25-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Red/black, Blue/Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
146-330 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Availability:
Yes

NEMIQ
Number of cores:
5 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Transparent
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare, Tinned
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
86 mm
Approved according to SS EN 60204:
Yes
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RKUB Förtent Single conductor - Coil


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Operating temperature:
-25-70 °C
Core colour:
Red, Black
Conductor surface:
Tinned
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
10-16.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RKUB Förtent Multi conductor - Coil


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Red/black
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Tinned
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
22.8-36 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RQ (H05Z-K, H07Z-K) - BOXWIRE

RKKB - Drum


NEMIQ
Number of cores:
1 .
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Max. conductor temperature:
70 °C
Nominal voltage:
60 V
Operating temperature:
-25-70 °C
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
21 mm

Kopplingskabel för solceller H1Z2Z2-K - Ring

R3 1-color - Spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Purple, Pink, Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-125 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Blue, Brown, Yellow, Grey, Green, Purple, Orange, Pink, Red, Black, White, Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
3.6-34.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

R3 2-colors - Spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-125 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
4.8-9.9 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

NEMIQFLEX-CY (EMC) - 100m


NEMIQ
Number of cores:
3-25 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Transparent
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
31.6-66.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

NEMIQFLEX-CY (EMC) - Drum


NEMIQ
Number of cores:
2-25 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes, No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Transparent
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
30.4-153.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
Yes

NEMIQ
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Brown
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-105 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
105 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Core colour:
Brown
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
4.29 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

2G4 - 100 m spool 1-color, 10-16 mm²


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-100 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
100 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
100 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Operating temperature:
-40-100 °C
Core colour:
Red, Black
Conductor surface:
Bare
Packaging:
Reel B4
Min. permitted bending radius, stationary application/permanent installation:
26.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RKUB Multi conductor - Drum


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Drain wire:
No
Conductor category:
Class 5 = flexible
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
15.2-18.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

RQ (H05Z-K, H07Z-K) - Box


NEMIQ
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70-90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300-600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare, Tinned
Halogen free:
Yes
Packaging:
Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
10.4-19 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RQ (H05Z-K, H07Z-K) - Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Black
Conductor surface:
Bare
Halogen free:
Yes
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
36.76-63.44 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes