Availability:
No

Availability:
No

Availability:
Yes

Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Core colour:
Green/yellow
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
No

Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Twisted cores:
No
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Core colour:
Red
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Availability:
No

Number of cores:
3 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
No
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
3 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
No
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
7 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
No
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
5 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
No
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
5 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
No
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
2 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
Yes
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
3 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
Yes
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
No

Number of cores:
5 .
Material outer sheath:
None
Colour outer sheath:
Black
Conductor material:
Copper
Screen:
Yes
Drain wire:
No
Conductor category:
Class 5 = flexible
Conductor surface:
Tinned
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Availability:
Yes

Availability:
Yes

Number of cores:
40 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
56.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No