Refined by
Hide irrelevant options
Product Category
Product Group
Colour
Nominal cross section conductor
Halogen free
Material insulation
Core insulation material
Halogen free (according to EN 60754-1/2)
Colour outer sheath
Core identification
Material outer sheath
Protective conductor
Reaction-to-fire class according to EN 13501-6
Armouring/reinforcement
Show all filters
Hide all filters
- Total: 9
RDOE (H07RN-F) - Drum
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage:H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 55-87.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RDOE (H07RN-F) - Drum 500 m
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Packaging: Drum
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage:H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 3-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 59.5-87.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RDO (H05RN-F)
H05RN-FConnection cable of rubber for use in power tools and light engineering equipment, which means high mechanical stresses occur, in both dry and humid rooms, even outdoors.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H05RN-F: 300/500V
Test voltage: H05RN-F: 2000V
Insulation Resistance > 1 Gohma x cm
Core identification H05RN-F:
2-conductor: blue, brown
3conductor: Green / yellow, blue, brown
4-conductor Green / yellow, brown, black, gray
5-conductor Green / yellow, blue, brown, black, gray
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-3 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -25-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- EPDM
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 33-41 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RDOE (H07RN-F) - Spool
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage: H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 750 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- EPDM
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 55-111 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX - PUR
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabelytterdiameter, höga mekaniska påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. Lämplig för användning i kabelkedjor och kontinuerligt rörliga maskiner samt
portalrobotar.
Uppbyggnad:
Ledare: Blank flertrådig koppar klass 6.
Ledarisolation: PP
Yttermantel: PUR, PURWIL
Mantelfärg: Grå, Orange
Ledarfärg - PUR: Svart med vit eller svart nummermärkning.
Ledarfärg - PURWIL: Färgade ledare enl. HD 308
Gröngul skyddsledare.
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm² -70mm²
Temp. område: Fast förläggning min/max: -40ºC till +90ºC
Rörlig förläggning min/max: -40ºC till +90ºC
Minsta böjradie: 5 x kabelns diameter
Oljebeständighet: God
Flambeständighet: IEC 332-1
Godkännanden: DIN EN 60811-404
VDE 0482 del 332-2-2 resp. IEC 60332-2-2
Tillämpade standarder: liknande VDE 0250
- Number of cores:
- 2-25 .
- Material core insulation:
- Rubber, Polyurethane (PUR)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyurethane (PUR)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Grey, Orange
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60-90 °C
- Screen:
- No
- Armouring/reinforcement:
- Braiding, None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey, Orange
- Material insulation:
- Polyurethane (PUR)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 27.5-97 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
MULTINORM-Y
HAR/UL-CSA styrkablar är särskilt lämpliga för exportinriktad tillverkning av maskiner, anläggningar och utrustning; på grund av de internationella godkännandena kan dessa styrkablar nästan användas över hela världen. De installeras i torra och fuktiga rum med medelstor mekanisk påfrestning och som anslutningskablar för statiska och icke-kontinuerliga böjningsapplikationer. Dessa kablar är dessutom extremt flexibla och används därför för värme- och kylinstallationer men inte utomhus eller för direkt nedgrävning.
Produkten motsvarar direktivet 2014/35/EU (lågspänningsdirektivet).
Uppbyggnad
Ledare: Blank flertrådig koppar class 5
Ledarisolation: Pvc
Ledarfärg: Svart med vit nummermärkning. Gröngul skyddsledare
Yttermantel: Pvc
Mantelfärg: Grå
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm²-70mm²
Temp. område: Fast förläggning min/max: 5ºC till +70ºC
Temp. område: UL+CSA: 5ºC till +90ºC
Isolationsmotstånd: > 20 MΩ x km
Minsta böjradie: 12,5 x kabelns diameter
Godkännanden:
Cpr klass: Eca
Självsläckande och flamskyddsmedel enl. till IEC
60332-1; VW1; CSA FT1
Standard EN 50525-2-51 / VDE 0285-525-2-51; UL style
2517/2587 och CSA C22.2 nr. 210.2-M90 AWM I A/B II
A/B
Standard EN 50525-2-51 / VDE 0285-525-2-51; UL stil
2517/2587 och CSA C22.2 nr. 210.2-M90 AWM I A/B II
A/B
Godkännande: HAR: 300/500 V - 70 ° C | UL / CSA 600 V - 90 ° C
- Number of cores:
- 3-5 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 32.4-40.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-H
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius.
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 VTest voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range:
Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Other
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Other
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- TPE
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 21.2-56 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H07BQ-F
Polyuretanmantlad och EPR-isolerad anslutningskabel för applikationer där kabeln utsätts för kraftigt mekaniskt slitage. Typiska användningsområden är handverktyg, på byggnadsplatser, i gruvindustrin, i maskininstallationer, samt inom livsmedelsteknisk- och kemisk industri. Kabeln är avsedd för torra eller våta rum, inom- och utomhus. Kabeln är halogenfri.
Uppbyggnad
Ledare: Fintrådig ledare av blank koppar
Ledarisolering: EPR-gummi.
Färgmärkta ledare Innermantel: EPR-gummi
Yttermantel: Polyuretan
Mantelfärg: Orange
Ledarfärger: Enl. DIN VDE 0293-308
Tekniska data:
Driftspänning: H07BQ-F: 450/750 V (>1,0 mm²;)
Provspänning: 2000 V AC
Temperaturområde: -40ºC till +75ºC
Minsta böjradie: 4 x kabelns ytterdiameter
Godkännanden: Flambeständighet CENELEC HD 22.10 S1
- Number of cores:
- 2-3 .
- Nominal voltage:
- 750 V
- Colour:
- Orange
- Material insulation:
- EPR, Polyurethane (PUR)
- Conductor surface:
- Bare
- Halogen free:
- No
NELCOFLEX-Y
Flexible oil resistant cable is resistant to the effects of chemicals and acids.
The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation
Best: 8 x 107 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500-1000 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 19.6-164.8 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 9