Logged in as:

Show all filters

Hide all filters

  • Total: 9

RDOE (H07RN-F) - Drum


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
55-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum 500 m


NEMIQ
Number of cores:
3-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
59.5-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDO (H05RN-F)


NEMIQ
Number of cores:
2-3 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-25-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
EPDM
Operating temperature:
-25-60 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
33-41 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RDOE (H07RN-F) - Spool


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
750 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
EPDM
Operating temperature:
-25-60 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
55-111 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

NELCOFLEX - PUR


-
Number of cores:
2-25 .
Material core insulation:
Rubber, Polyurethane (PUR)
Specification core insulation:
Other
Core identification:
Colour, Numbers
Protective conductor:
Yes, No
Material outer sheath:
Polyurethane (PUR)
Specification material outer sheath:
Other
Colour outer sheath:
Grey, Orange
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60-90 °C
Screen:
No
Armouring/reinforcement:
Braiding, None
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey, Orange
Material insulation:
Polyurethane (PUR)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
27.5-97 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

MULTINORM-Y


-
Number of cores:
3-5 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
32.4-40.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes

NELCOFLEX-H


-
Number of cores:
2-25 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes, No
Material outer sheath:
Other
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
TPE
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
Yes
Min. permitted bending radius, stationary application/permanent installation:
21.2-56 mm
Reaction-to-fire according to EN 13501-6: Class:
Dca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

H07BQ-F


-
Number of cores:
2-3 .
Nominal voltage:
750 V
Colour:
Orange
Material insulation:
EPR, Polyurethane (PUR)
Operating temperature:
-40-75 °C
Conductor surface:
Bare
Halogen free:
No

NELCOFLEX-Y


-
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour, Numbers
Protective conductor:
Yes, No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500-1000 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
19.6-164.8 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
  • Total: 9