Refined by
Hide irrelevant options
Product Category
Product Group
Single insulated/Double insulated
Colour
Nominal cross section conductor
Halogen free
Packaging
Material insulation
Conductor Surface
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Screen
Core identification
Flame retardant
Material outer sheath
Conductor category
Protective conductor
Low smoke (according to BS EN 61034-2)
Reaction-to-fire class according to EN 13501-6
AWG size
Armouring/reinforcement
Twisted cores
Show all filters
Hide all filters
RK BOX
Used as connectors line and installation line.
Structure
Conductors: Bare stranded copper
Conductor Insulation: PVC
Core identification: The table below
Technical data:
Rated voltage:
HO5V-K 0.5-1.0 mm²: 300/500 V
HO7V-K 1.5-120 mm²: 450/750 V
Test voltage:
HO5V-K 0.5-1.0 mm²: 2000 V
HO7V-K 1.5-120 mm²: 2500 V
Temperature range: -5ºC to +70ºC (+23ºF to +158ºF)
Minimum bend radius: 12 x cable diameter
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Green/yellow
- Material insulation:
- Polyvinyl chloride (PVC)
- Designations:
- H07V-K (RK 1.5 - 400mm2)
- Core colour:
- Green/yellow
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 15.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
TX UL 3746
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin.
Idealisk för installation inuti rör samt för utanpåliggande installation. Mycket goda elektriska och mekaniska egenskaper.
Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan.
Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
Halogenfri.
Uppbyggnad
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation: XHFFR
Mantelfärg: Se produktdata nedan
Tekniska data:
Driftspänning: 300 V
Temp.område: -40ºC till +105ºC
Godkännanden, flambeständighet
IEC60754-1
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- XLPE
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 4.05-6.42 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
DINFLEX-Y (LiYY) - Korta längder
Flexible electronic cable with fine wire conductor structure, as in combination with PVC sheath it provides a very flexible cable with a small bending radius. It is used for signal, measurement, control and tone-frequency transmission in electronics, computers and signal systems.
Structure Conductor: Blank stranded copper
Conductor insulation: PVC
Core identification: According to DIN 47100
Outer Sheath: PVC
Sheath identification: Grey
Technical data:
Rating voltage: 0.14 mm² = 350 V >; 0.14 mm² = 500 V
Test voltage: 0.14 mm² = 800 V >; 0.14 mm² = 1200 V
Temperature range: Fixed min/max: -30ºC to +70ºC (-22ºF to +158ºF)Moving min/max: -5ºC to +70ºC (-22ºF to +158ºF)
Radiation Resistance: 8 x 107 cJ/kg
Minimum bending radius: 10 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
- Number of cores:
- 2-37 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 16-64.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKUB Förtent Single conductor - Coil
Connection cable for car and boat applications.
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Red
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Packaging:
- Ring
- Min. permitted bending radius, stationary application/permanent installation:
- 10-16.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Korta längder
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 31.6-105.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-H
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius.
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 VTest voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range:
Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Other
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Other
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- TPE
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 21.2-56 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIF
Connecting cable with insulation of silicone rubber. The wire is particularly suitable as internal wiring in light fixtures, furnaces, heaters and appliances, where the wire is continuously exposed to high temperatures. The wire is halogenfree.
Packaging: Coil
Structure:
Conductors: Stranded tinned copper
Conductor Insulation: Silicone rubber
Core identification: The table below
Technical data:
Rated voltage: 300/500V
Test voltage: 2000V
Temperature range: -50ºC to +180ºC (-58ºF to 356ºF)
Minimum bend radius:
Moving: 12 x cable diameter
Fixed: 6 x cable diameter
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -60-185 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 185 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Silicone
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Ring
- Min. permitted bending radius, stationary application/permanent installation:
- 7.5-19.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Trumma
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 30.4-153.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
R3 1-color - Spool
Flame retardant thermoplastic cable XHFFR, suitable for vehicles use on low voltage applications and systems, without direct contact of heat sources on the cable.
Suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Technical data
100V
Temp. range: -40º C to + 125º C
Approvals:
ISO 6722 class C
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Purple, Pink, Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Pink, Red, Black, White, Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 3.6-34.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
R3 2-colors - Spool
Flame retardant thermoplastic cable XHFFR, suitable for vehicles use on low voltage applications and systems, without direct contact of heat sources on the cable.
Suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Technical data
100V
Temp. range: -40º C to + 125º C
Approvals:
ISO 6722 class C
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 4.8-9.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-Y
Flexible oil resistant cable is resistant to the effects of chemicals and acids.
The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Color-coded conductors. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation
Best: 8 x 107 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500-1000 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 19.6-164.8 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125B Multi conductor screened
Halogenfri kabel lämpligt både för fast förläggning eller som anslutningskabel i torra, fuktiga och våta utrymmen både inom- och utomhus.
Med hänsyn av de goda mekaniska egenskaper samt den höga kemikaliebeständigheten, är RADOX 125 speciellt lämplig inom industrin i krävande miljöer, t.ex för maskiner och industriutrustningar. Kabeln har flätad kopparskärm med hög täckningsgrad, därför är den mycket lämplig i miljöer med hög störningsnivå (enligt EMC-direktivet).
- Number of cores:
- 2-12 .
- Protective conductor:
- No
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Nominal voltage:
- 1000 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
RADOX TENUIS -TW 600V MM
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces, smaller, lighter and more flexible than previous cables for railway application.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Guidelines for selection and installation are described in the standards EN 50355 and EN 50343. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX EI 303 (polyolefin copolymer)
Conductor color: White, numbered and g = green / yellow. Transparent plastic foil
Conductor insulation outer sheath: RADOX EM 104 (polyolefin copolymer)
Sheath color: Black with yellow text
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals:
EN 50355 and EN 50343, flame resistance
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-12 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX MARIN MFH-S B
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 3 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 17.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX MARIN MFH-S B, Twisted pair
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 8-28 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 31.5-42.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTOL 155 TAPE
Batterikabel som har (FHLR91X Enligt DIN76722) utmärkt beständighet mot hög och låg temperatur, ozon- och väderbeständighet, beständig mot högt tryck, temperatur, motorolja, bränslen och hydrolys, flamskyddsmedel, hög nötningsbeständig, lödbeständig, lätt att skala och bearbeta tack vare tape, enligt ISO 6722 klass D, LV 112, ISO 14572, LV 212, DIN 76722.
Uppfyller EU - direktiv 2000/53 / EG om uttjänta fordon. Det är fritt från bly, kvicksilver, kadmium och krom VI.
Användning: Lågspänningskabel, för användning i bla hybrid- och elfordon, lastbilar.
FÖRSIKTIGHET: Särskild försiktighet ska iakttas för kablar som används med spänningar över 60 VDC för att skydda dem från mekanisk belastning för att undvika stötar (ISO 6722: 2006)
Ledare: Glödgad koppar enligt ISO C flexibel 6
Ledarisolation: 155S (polyolefin) Mantelfärg: Se produktdata.
Tekniska data:
Driftspänning: 1000VAC 1500VDC
Provspänning AC: < Temp. område: -40ºC till +150ºC (3000H)
Minsta böjradie: 3 x kabelns diameter
Godkännanden, Standarder: ISO 6722 class D iSO 19642-9
- Colour outer sheath:
- Red
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Red
- Halogen free:
- Yes
Microwavecable assemblies
RF-kablage, mikrovågor. Minibend-serien är en flexibel, förmonterad koaxialkablage designad för interna punkt-till-punkt-sammankopplingar mellan RF-moduler inom system.
Serien tillåter böjning omedelbart bakom kontaktdonet, med utmärkt motståndskraft mot flammor och korrosion, och har imponerande dragstyrka och mekanisk hållbarhet. Den är 100 % testad för att säkerställa högsta kvalitet.
Tillämpbar i frekvenser upp till 65GHz.
100 % testad förmonterad koaxialkabelenhet.
Patenterad lödfri kabelförgrening.
Fördelar med Minibend-serien:
Böj mot änden: gör det möjligt att böja kabeln omedelbart bakom kontakten
Utmärkt dragstyrka och mekanisk hållbarhet
Högpresterande kabelmontage med utmärkt motståndskraft mot lågor och korrosion
Används inom försvar & test &mätning.
RADOX 9 GKW-AX 3600/6000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 3.6/6.0 kV AC, 4.5/9.0 kV DC
Provspänning: 12 kV (50 Hz, 15 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet:
BS 6853
DIN 5510
NF F16-101
BS 4066-3,
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1,
EN 50265-2-1 IEC 60332-3-24,
EN 50266-2-4 IEC 60754-1,
EN 50267-2-1 IEC 60754-2,
EN 50267-2-3 IEC 61034-2,
EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3600 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS401
- Low smoke (according to EN 61034-2):
- Yes
RADOX TENUIS -TW 600V MM S
Halogenfri skärmad styrkabel för skyddad fast förläggning i tågapplikationer. Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen, mindre, lättare och mer flexibel än tidigare kablar för järnvägsapplikation.
Användningsområden:
Styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Riktlinjer för val och installation beskrivs i standarderna EN 50355 och EN 50343. Tålig mot hög mekanisk belastning, olja och bränsle.
Skärmflätan av förtent koppar skärmar den inre strömkretsen mot omgivningen samt ger ett extra mekaniskt skydd. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX EI 303 (polyolefin-copolymer) Ledarfärg: Vita, numrerade samt g = grön/gul .
Skärm: Förtent kopparfläta
Täckningsgrad c:a 85%.Transparant plastfolie
Ledarisolation yttermantel: RADOX EM 104 (polyolefin-copolymer)
Mantelfärg: Svart med gul text
Tekniska data:
Driftspänning: 600/1000 V AC, 750/1500 V DC
Provspänning: 3500 V (50 Hz, 5 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden:
EN 50355 samt EN 50343, flambeständighet
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265-2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-6 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX AUTO B FLEX - Single conductor
Shielded power cable for use in hybrid and electric vehicles (FLR 41XC33X)
Excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in trucks, among other things.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Annealed copper according to ISO C flexible 6
Conductor insulation: 155 (polyolefin)
Coat color: Orange
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage: 50HZ, 1MIN 3500 kV AC
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius:
Fixed 4 x the diameter of the cable
Flexing 4 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
MICROWAVE HAND FORMABLE
Formstabila, handformbara alternativ till halvstyva (semi-rigid)
mikrovågskablar .
Tillgängligt endast som kablage på förfrågan.
RADOX AUTOL 155S FLR-A
Vehicle cable that has (FHLR91X According to DIN76722) excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure, temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in hybrid and electric vehicles, trucks, among others.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155S (polyolefin)
Coat color: See product data.
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage AC: <
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 3 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Green, Orange, Red, Black, White
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -40-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes, No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated, Double insulated
- Colour:
- Black, Green, Orange, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Green, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes, No
- Packaging:
- CK2
- Min. permitted bending radius, stationary application/permanent installation:
- 4.5-6.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
EN-Cable, multi conductor
Halogenfria, elektronstråle-tvärlänkade kablar med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyll kraven EN 50264-3-2
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift. Riktlinjer för val och installation beskrivs i standarderna EN 50355 och EN 50343.
RADOX EN 50264- 3- 2 ,EN 50306-4600V MM Flerledarkablar med reducerade väggmått
Nominell spänning: 600 / 1000 V AC
Risknivå: MM (extra låg temperatur, extra olja och extra bränslebeständig)
- Number of cores:
- 2-3 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 24.9-26.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3 GKW/S EMC
Halogenfri styrkabel för skyddad fast förläggning i tågapplikationer. Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen.
Användningsområden är styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Tålig mot hög mekanisk belastning, olja och bränsle.
- Number of cores:
- 3-8 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes, No
- Armouring/reinforcement:
- Braiding, None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 48.6-240.24 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No