RADOX 155 - Industribobin
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Grey, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, Green/yellow, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Grey, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-10.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3271
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Drum, Spool HS400, Spool HS401
- Min. permitted bending radius, stationary application/permanent installation:
- 7.8-33.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 1 .
RADOX UL3266
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS151, Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 3.96-7.23 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 4 GKW-AX 1800/3000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS401
- Low smoke (according to EN 61034-2):
- Yes
RADOX 125 - Industry Spool
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS150, Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-10.05 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3 GKW 600/1000 V - Single conductor
Halogenfri kopplingskabel för fast förläggning i tågapplikationer, lamparmaturer, elektriska applikationer samt kabeldragning i vagnar, terminaler och annan kraftförsörjningsapparatur. Tålig mot hög mekanisk belastning, olja och bränsle.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Grey, Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, Green/yellow, Red, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Grey, Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS401, CK, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 6-53.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NSGAFÖU
Dubbelisolerad kopplingskabel i oljebeständigt och flamhämmande utförande. Har en inner- och yttermantel av special gummi vilket gör att den tål hög mekanisk belastning. Kortslutnings- och jordfelssäker upp till 1000 V. För installationer i bussar, tåg och i kopplingsskåp. Lämpar sig även för anslutning till rörliga enheter.
Märkspänning: Uo/ U1,8/3kV
Ledaruppbyggnad: Klass 5 = mångtrådig
Material Ledare: Förtent koppar
Ledarisolering: EPR gummi
Yttermantel: Specialgummi, polykloropren
Färg på yttermantel: Svart
Böj radie fast förläggning: 6 x kabeldiametern
Böj radie rörlig förläggning: 10 x kabeldiametern
Min temperatur fast förläggning: -40°C
Max temperatur fast förläggning +80°C
Min temperatur rörlig förläggning: -25°C
Max temperatur rörlig förläggning: +80°C
Provspänning: 6000V
Isolationsresistans: ≥20 M Ohm x km
Max temperatur ledare: +90°C
Brandspridningsklass: IEC 60332-1
Tillverkningsnorm: VDE 0295, IEC 60228
Godkännande. VDE 0250 Part 602
- Number of cores:
- 1 .
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Neopren (CR)
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Reel B5
RK Förtent (H05V-K, H07V-K)
Used as connectors line and installation line.
Structure
Conductors: Bare stranded tinned copper
Conductor Insulation: PVC
Core identification: The table below
Technical data:
Rated voltage:
HO5V-K 0.5-1.0 mm²: 300/500
VHO7V-K 1.5-120 mm²: 450/750 V
Test voltage:
HO5V-K 0.5-1.0 mm²: 2000
VHO7V-K 1.5-120 mm²: 2500 V
Temperature range: -5ºC to +70ºC (+23ºF to +158ºF).
Minimum bend radius: 12 x cable diameter
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Green/yellow, Red, Black
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 12.4-15.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIF UL3239
Allmänt
Silikongummi är gjord för att tåla höga temperaturer.
I applikationer där mekaniskt slitage bryter ner andra typer av kablar, kan man använda kopplingstråd isolerad med silikongummi. Dessa kopplingstrådar är bra för värme- och belysningssystem, gjuterier, fabriker, kvarnar och brännare.
Teknisk data
Material Ledare: Förtent koppar
Ledaruppbyggnad: Klass 5
Ledarisolering: Silikongummi
Max. Temperatur: 150°C
UL Style 3239
Spänning: 40000 kV
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -60-150 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 150 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Core colour:
- Red
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 7.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Twisted cores:
- No
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Core colour:
- Green/yellow
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Twisted cores:
- No
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Core colour:
- Red
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Brown
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Core colour:
- Brown
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 4.29 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No