Hand tools that can be used for soldering and shrinkage of shrink tube and shrink cable shoe. The tools contain a standard lighter that can easily be replaced.
Glow instead of open flame.Supplied with reflector.Glowing temperature about 350 degrees Celsius .
Length: 125 mm
Ratcheting ring wrench with insulated handle.
Lockable rotation. Every tool has two different sized sockets.
Material: CrV Steel1000V-rated insulating handle.
Connection cable for car and boat applications.
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Operating temperature:
-25-70 °C
Core colour:
Red, Black
Conductor surface:
Tinned
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
10-16.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
För Mega S-säkringar.
Säkringen skruvas fast mellan 2 stycken M5 muttrar. Hållaren fästs med 2 bultar.
Flera hållare kan även monteras ihop på rad.
Maximal kabeldiameter: 10 mm OBS! Säkring ingår ej.
Dimensioner (L x B x H): 60 mm x 28 mm x 30 mm
För Mega L-säkringar med lock.
Säkringen skruvas fast med 2 stycken M8 muttrar. Hållaren fästs med 2 bultar.
Maximal kabeldiameter: 25 mm OBS! Säkring ingår ej.
För 2 stycken Mega L-säkringar med lock.
Säkringen skruvas fast med 2 stycken M8 muttrar. Hållaren fästs med 4 bultar.
Maximal kabeldiameter: 25 mm OBS! Säkring ingår ej.
Rörkabelskor 2-håls, KRD. För fåtrådig kabel (klass 2).
Material: 99.9% ren Cu
Ytbehandling: > 4µ Sn
Märkning på rörkabelskons platta kan t.ex. vara: n35-12D
n = Nemiq // 35 = 35 mm² kabel // 12 = M12 hål // D = KRD // F = KRF // T = KRT
Märkning på rörkabelskons hals kan t.ex. vara: 13
13 = Ytterdiameter på halsen (OD-måttet).
Vid pressning med 6-kantsbackar skall halsmärkning och backmärkning överensstämma.
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD ,T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
For stranded wires (class 5 and class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
H1Z272-K solar cell connection cable offers an optimal solution when it comes to connecting solar panels to each other or with junction boxes and frequency converters. The cable is very resistant to mechanical impact. Good properties in terms of temperature range, chemical resistance, UV resistance and short-circuit resistance. The cable is halogen free.
Construction:
Conductor: Tinned copper according to IEC 60228 class 5
Conductor insulation:
Inner sheath: POLYOLEFIN
Outer sheath: POLYOLEFIN
Coat color: See product facts
Technical data:
Minimum bending radius:
Variable = D < 8 mm² x cable diameter Ø
Fixed = D > 8 mm3 x cable diameter Ø
Temperature range: -40ºC to + 110ºC
Rated voltage: Uo / U AC: 1000V, DC: 1500V
Test voltage: 6500VAC
Approvals:
EN 50575: 2014
EN 50575 / A1: 2016 CE EN 50618 CPR Eca
Flame retardant thermoplastic cable, suitable for vehicles
use on low voltage applications and systems, even in hot environments, without direct contact of heat sources on the cable. Heat-resistant cable, suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Coat color: See product data
Technical data:
100V
Temp. range: -40ºC to + 125ºC
Approvals:
ISO 6722 class C
Flame retardant thermoplastic cable, suitable for vehicles
use on low voltage applications and systems, even in hot environments,
without direct contact of heat sources on the cable. Heat-resistant cable, suitable for applications inside the engine compartment.
Packaging (OD x Hub x Width):
Spool B6: 250mm x 56mm x 95mm
Construction:
Conductor: Annealed multi-wire copper class 3
Leader insulation: XHFFR
Sheath color: Black
Conductor color: See product data
Technical data:
100V
Temp. range: -40ºC to + 125ºC
Approvals:
ISO 6722 class C
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.