Logged in as:

Show all filters

Hide all filters

SKUB Tvillingkabel


NEMIQ -
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-25-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Red/black, Blue/Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
146-330 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK BOX


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Green/yellow
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Green/yellow
Conductor surface:
Bare
Halogen free:
No
Packaging:
Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
15.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

DINFLEX 67


NEMIQ
Number of cores:
4-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-80 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
80 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Other
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
250 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-5-80 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
22.5-85.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX 43


NEMIQ
Number of cores:
4-16 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Other
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
250 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
24-50 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Texiline


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Blue, Brown, Grey, Green/yellow, Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
6-14.7 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

H01N2-D FT - Spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
58.2-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

DATAFLEX - Korta längder


NEMIQ
Number of cores:
4-6 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
250 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
27.5-45 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-CY (LiYCY) - Spool 100m


NEMIQ
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
18.5-64.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Crimp tool - Basic


NEMIQ -
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors, Screen connector
Construction/operation:
Mechanical
For component:
Insulated terminals, Non-insulated terminals, roller compaction, Coaxial
Compression shape:
Hexagon, Oval pressing, Roll compression (shrinking)

Svetskabel - Dubbelisolerad, trumma


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Yellow
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Yellow
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Yellow
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Installation Kit – Solar Panel Connectors


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
Yes
Number of included inserts:
1-2 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Ratchet model mechanical
Compression shape:
Square compression, Roll compression (shrinking), Universal (exchangeable inserts)

Tool set specially designed for electricians


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
Yes
Number of included inserts:
3 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Various applications
Construction/operation:
Mechanical
Compression shape:
Universal (exchangeable inserts)

NELCOFLEX-CY (EMC) - 100m


NEMIQ
Number of cores:
3-25 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Numbers
Protective conductor:
Yes
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Transparent
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
31.6-66.4 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Locking spade terminal SPN-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polyvinyl chloride (PVC)
Fire classification:
According to UL94V2
Operating temperature:
-40-105 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
UL-File No.:
E78965
Yes
Yes
V2

Spade terminals PB-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red, Other
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
UL-File No.:
E44245
Yes
Yes
V2

Pin terminals PB-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Pin shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
UL-File No.:
E44245
Yes
Yes
V2

Locking spade terminal PB-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
UL-File No.:
E44245
Yes
Yes
V2

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Max. current (Imax):
19-27 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
UL-File No.:
E44245
Yes
Yes
V2

Ring terminals on reel, ICTBX-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Max. current (Imax):
19-27 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Blue, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
UL-File No.:
E44245
Yes
Yes
V2

Gaffelkabelskor med bockad framkant PB-serien


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Partially isolated
Colour insulation:
Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material insulation:
Polycarbonate (PC)
Fire classification:
According to UL94V2
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
UL-File No.:
E44245
Yes
Yes
V2

Heat-shrink insulated Ring terminals DS-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-125 °C
Material:
Copper
Voltage max:
600V
Yes
Yes

Heat-shrink insulated Spade terminals DS-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Fork shape
According to DIN:
No
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-55-125 °C
Material:
Copper
Voltage max:
600V
Yes
Yes

Flaggkabelskor


NEMIQ
Reel/roll packaging:
No
Model:
Bushing
Max. current (Imax):
8-10 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Brass
Neck type:
Open barrel crimp
Yes

Flatstiftshylsor med nabb


NEMIQ
Model:
Bushing
Max. current (Imax):
8-24 A
Insulation:
Not isolated
Colour insulation:
Other
With cam clamp:
No
With tap spreader:
No
Material insulation:
Other
Operating temperature:
-10-110 °C
Material:
Bronze, Brass
Neck type:
Open barrel crimp
Packaging:
Loose piece
Yes
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.