Refined by
Hide irrelevant options
Produktgrupp
Show all filters
Hide all filters
RKUB Förtent Multi conductor - Spools
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B4: 160mm x 56mm x 90mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Red/black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Packaging:
- Reel B4
- Min. permitted bending radius, stationary application/permanent installation:
- 18.8-36 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKUB Förtent Single conductor - Spools
Connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Structure:
Conductor: Tinned stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Red
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Packaging:
- Reel B3, Reel B4
- Min. permitted bending radius, stationary application/permanent installation:
- 10-16.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
Battery Crimp Tool for DHD-Crimp dies
NMBT DHD battery crimp tool for DHD, DRG & NCXD-diesets. The crimp head can be rotated 350º. Delivered with battery(with indicator) and charger in plastic case
Battery: 18 VDC, 2.0 Ah Li-IonPressure: 14,7kN, 1.5tonWeight: 1.9kg (inklusive batteri) Dimension case (LxWxH): 560x160x400 mm
- With locking device (for mechanical tools):
- No
- Inserts exchangeable:
- Yes
- Number of included inserts:
- 0 .
- With automatic return:
- No
- Cycle time:
- 3 s
- Compression force:
- 14.7 kN
- Suitable for:
- Various applications
- Construction/operation:
- Accumulator-hydraulic
- For component:
- Shrink terminals, End sleeves, Turned contacts, Deutsch, Insulated terminals, Non-insulated terminals, roller compaction, Non-insulated Cu tube and sheet terminals, Modularplugg, Wirelås
- Compression shape:
- Universal (exchangeable inserts)
Crimp tool - K 2
Pressverktyg för rörkabelskor och plåtkabelskor, utrustad med ergonomiska 2-komponenthandtag och långa skänklar för att underlätta pressningen.
En ratchettång med inbyggd returspärr som garanterar att kontaktpressningen fullföljs.
- With locking device (for mechanical tools):
- Yes
- Inserts exchangeable:
- No
- Number of included inserts:
- 1 .
- With automatic return:
- Yes
- Cycle time:
- 2 s
- Suitable for:
- Cable lugs and connectors
- Construction/operation:
- Mechanical
- For component:
- Non-insulated Cu tube and sheet terminals
- Compression shape:
- Arbour clamping
Crimp tool - ETP 0146
Pressverktyg med frontpressning av ändhylsor 0.14 – 6 mm² i samma uttag.
En ratchetttång som säkerställer att pressningen fullföljs.
- With locking device (for mechanical tools):
- Yes
- Inserts exchangeable:
- No
- Number of included inserts:
- 1 .
- With automatic return:
- Yes
- Cycle time:
- 2 s
- Suitable for:
- Cable end sleeves
- Construction/operation:
- Mechanical
- For component:
- End sleeves
- Compression shape:
- Trapezoid compression
Crimping Tool Ferruls - EHX 00816
A crimping tool to ensure accurate and efficient crimps of ferrules in sizes 0.08-16mm² and twin ferruls 0.25-10mm² in the same die.
It is a ratchet-style tool that adjust to fit various terminal sizes; ensuring a precise and reliable crimp every time
The tool has a guide to facilitate the centering of the smaller sleeves.
- With locking device (for mechanical tools):
- Yes
- Inserts exchangeable:
- No
- Number of included inserts:
- 1 .
- With automatic return:
- Yes
- Cycle time:
- 2 s
- Suitable for:
- Cable end sleeves
- Construction/operation:
- Mechanical
- For component:
- End sleeves
- Compression shape:
- Hexagon
Crimp tool – CSV10
Pressverktyg där CVS10-huvudet även kan användas i WDT UP35 och UP60.
En ratchetttång som säkerställer att pressningen fullföljs.
- With locking device (for mechanical tools):
- Yes
- Inserts exchangeable:
- No
- Number of included inserts:
- 1 .
- With automatic return:
- Yes
- Cycle time:
- 2 s
- Suitable for:
- Cable lugs and connectors
- Construction/operation:
- Mechanical
- For component:
- Turned contacts, Deutsch, Un-insulated flag terminal
- Compression shape:
- Roll compression (shrinking), Other
KRT - Cable lugs angled +45º
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D= KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-124 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KRT - Cable lugs with two stud holes - 10-500mm²
"2-holed copper tube lugs, KRT.
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform."
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 97-227 A
- Number of mounting holes:
- 2 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRT/KST(10-500mm2)
KRTS - 35-300mm²
KRTS-serien är rörkabelskor anpassade för trånga utrymmen. Kabelskoplattan är i samma bredd som kabelskon halsdiameter. Passar till mångtrådiga Cu-ledare(klass 5) samt fåtrådiga Cu-ledare(klass 2).
Material: 99.9% ren Cu
Ytbehandling: > 4µ Sn
Märkning på rörkabelskons platta kan t.ex. vara: n35-6T
n = Nelco // 35 = 35 mm² kabel // 6 = M6 hål // T = KRT måttstandard.
Märkning på rörkabelskons hals kan t.ex. vara: 12
12 = Ytterdiameter på halsen (OD-måttet).
Vid pressning med 6-kantsbackar skall halsmärkning och backmärkning överensstämma.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 153-560 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- Yes
- With sight-hole:
- No
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRTS
KR - Cable lugs angled -90º
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 30-51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 90°
- Series:
- KR/KS (0.75-6mm2)
KRF - Cable lugs angled +45º
For stranded wires. (class 5 and class 6)
Material: 99.9% pure copper
Surface: > 4µ Sn
Temperature range: Up to 200° C (392º F)
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 153-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRF/KSF (10-500mm2)
KR - Cable lugs angled -45º
Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD ,T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 51 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KR/KS (0.75-6mm2)
KRT - Cable lugs angled -45º
Copper tube lugs for stranded (class 5) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12T
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // T = KRT, F = KRF, D = KRD
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 227-395 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRT/KST(10-500mm2)
KRF - Cable lugs angled -45º
For stranded wires (class 5 and class 6).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs palm can for ie be: n35-12F
n = nemiq // 35 = 35 wire // 12 = M12 stud size. // F = KRF, D= KRD, T = KRT
Inscriptions on the lugs neck can for ie be: 13
13 = Outside diameter of the neck (OD).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 97-842 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 45°
- Series:
- KRF/KSF (10-500mm2)
KRF - 10-25mm²
Fork terminals.
Material: 99.9% pure copper
Surface: > 4mc Sn
Inscriptions on the lugs palm can for ie be: 4-6
4 = 4 mm² wire // 6 = M6 stud size.
- Suitable for Class 5 conductor:
- Yes
- Suitable for Class 6 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-124 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Fork shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- Yes
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KR/KS (0.75-6mm2), KRF/KSF (10-500mm2)
KRT 10-400mm² without inspection hole
Meets the measure requirements according to DIN 46235. Copper tube lugs for stranded (class 5 and class 6) and solid wires (class 2).
Material: 99.9% pure copper
Surface: > 4µ Sn
Inscriptions on the lugs neck can for ie be: 12
12 = Outside diameter of the neck (F).
When crimping with hexagon dies neck inscription and die markings must conform.
- Suitable for Class 2 conductor:
- Yes
- Suitable for Class 5 conductor:
- Yes
- Insulated:
- No
- Max. current (Imax):
- 66-288 A
- Number of mounting holes:
- 1 .
- Flange shape:
- Ring shape
- Colour insulation:
- Other
- Slender flange model:
- No
- With sight-hole:
- No
- Conductor category:
- Several
- Max Temp:
- 150 °C
- Surface protection:
- Tinned
- Material:
- Copper
- Connecting angle:
- 180° (horizontal)
- Series:
- KRT/KST(10-500mm2)
N 2258
N 2258 is a crimping tool for 6.0-16.0 mm² CUT, KR/KS 4.0-6.0 mm² and KRF/KSF 10.0-16.0 mm².
There are 3 die nests:
1: Cut 6.0-10.0 mm² & KR/KS 4.0-6.0 mm²
2: Cut 16.0 mm² & KRF/KSF 10.0 mm²
3: KRF/KSF 16.0 mm²
Length: 260 mm
- With locking device (for mechanical tools):
- Yes
- Inserts exchangeable:
- No
- Number of included inserts:
- 1 .
- With automatic return:
- Yes
- Cycle time:
- 2 s
- Suitable for:
- Cable lugs and connectors
- Construction/operation:
- Mechanical
- For component:
- Non-insulated Cu tube and sheet terminals
- Compression shape:
- Hexagon, Arbour clamping
RKUB Multi conductor
Connection cable for car and boat applications. The cable comes on spool of 50 m or 100 m. See table below.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Spool B5: 200mm x 56mm x 88mm
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Core identification: According to table below
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2-4 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Transparent, Red/black, Blue/Black, Brown/Brown, Brown/Red, Brown/Black, Grey/Grey, Red/Red, Red/Black/White/Blue, Black/Black, White/White
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Reel B3, Reel B4, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 15.2-44.8 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes, No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKKB - Spool
Round flexible cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Spool B5: 200mm x 56mm x 88mm
Drum
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Identification line up on conductors: Grey, black, red, blue, yellow, green, brown, white, purple, pink
Outer Sheath: PVC
Sheath identification: Grey, black, white
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2-17 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Grey, White
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Reel B3, Reel B4, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 18.4-61.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RKXB - Spool
Flat flexible connection cable for car and boat applications.
Packaging (OD x Hub x Width):
Spool B3: 160mm x 56mm x 50mm
Spool B4: 160mm x 56mm x 90mm
Spool B5: 200mm x 56mm x 88mm
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Core color (unless otherwise specified): Gray, black
Outer Sheath: PVC
Sheath Colour: Grey, black
Technical data:
Rating voltage: 60V
Temperature range: -25ºC to +70ºC (-13ºF to +158ºF)
- Number of cores:
- 2-3 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Grey
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Ring, Reel B3, Reel B4, Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 20.8-37.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
MKKB
Cable used mainly in motor vehicles as ignition cable. It is built of a multi-wire standard copper conductor and insulation and sheath of standard PVC that can withstand temperature range -25 -C to + 70ºC.
Packaging (YD x Hub x Width)
Bobin B3: 160mm x 56mm x 50mm
Max voltage: 15kV
Outer diameter: 5.2mm
Structure
Conductor: Stranded copper
Outer sheath: PVC, double insulated
Coat color: Black or Red
- Number of cores:
- 1 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black, Red
- Core colour:
- Red, Black
- Conductor surface:
- Bare
- Packaging:
- Reel B3
- Min. permitted bending radius, stationary application/permanent installation:
- 21 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
Grommets, gummigenomföring
Cable grommets to protect cables when insertion of cables through the holes for example in an apparatus box. Has good electrical insulation. Suitable for electric applications. Good resistance to oils and ozone.
Material: Polychloroprene rubber
Temperature range: -30 degrees Celsius to +90 degrees Celsius
- Gastight:
- No
- Degree of protection (IP):
- IP00
- Watertight:
- No
- Fire resistant:
- No
- Angle model:
- No
- With strain relief:
- No
- Model:
- Open
- Material quality:
- Other, Thermoplastic
- Shrink technique:
- No
- Insert for cable gland:
- No
- Cable entry:
- Round
- Number of cables:
- 1 .
- Colour:
- Black
- Surface protection:
- Untreated
- Material:
- Rubber, Plastic
- Halogen free:
- Yes, No
ADR-kabel
Low-voltage cable in PVC / PVC / PUR for transportation of dangerous material in accordance with DIN 72 570 Teil 10, GGVS / ADR Anhang B2. ADR cable is designed for use in commercial vehicle manufacturing. It is used for electrical installations on various types of trailers and truck trailers for transport of dangerous material as GGVS / ADR. The cables are UV and cold resistant, and thanks to the sheath material of PUR, in large extent it is even oil-, weather- and chemical resistant. The outer sheath of PUR makes the cable rubbing resistant, micro resistant and hydrolysis resistant. The cables are developed according to international standard, ISO 4141.
Packaging: Coil/Drum
Structure
Conductor: Stranded blank copper wire.
Conductor insulation: PVC-based conductor insulation. The conductors twisted in layers.
Inner Sheath: Special mixture on PVC base.
Outer Sheath: Special polyurethan (PUR), black.
Color code: According to ISO 4141-3, see pdf under documents.
Technical data:
Rating peak voltage (not for strong Power): 60V
Test voltage: 5 kV, minimum 5 minutes
Insulation resistance: 10 Mohm x km
Minimum bending radius: 12 x cable diameter
Temperature range: -40ºC to +85ºC
Conductor Structure: Stranded EN 60288.5
Approvals: ISO 4141 and DIN / ISO 6722ADR / GGVS
- Number of cores:
- 2-15 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyurethane (PUR)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -30-85 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 85 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 60 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Bare
- Packaging:
- Ring
- Min. permitted bending radius, stationary application/permanent installation:
- 54.08-170.56 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No