Crimp tool - CS30


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Mechanical
For component:
Non-insulated terminals, roller compaction
Compression shape:
Roll compression (shrinking)

Pressverktyg för Modularkontakter – ASR 486


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Mechanical
For component:
Modularplugg
Compression shape:
Notching

Pressverktyg för modularkontakter - MPC


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Mechanical
For component:
Modularplugg
Compression shape:
Notching

NP 695


NEMIQ
With locking device (for mechanical tools):
Yes
Inserts exchangeable:
No
Number of included inserts:
1 .
With automatic return:
Yes
Cycle time:
2 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Mechanical
Compression shape:
Arbour clamping

Kopplingskabel för solceller H1Z2Z2-K - Trumma


NEMIQ
Single insulated/Double insulated:
Double insulated

R3IB - Single conductor


NEMIQ
Single insulated/Double insulated:
Double insulated
Yes

R3IB - Multi conductor


NEMIQ
Single insulated/Double insulated:
Single insulated
Yes

Hydrauliskt presshuvud för backsystem


NEMIQ
With locking device (for mechanical tools):
No
Inserts exchangeable:
Yes
Number of included inserts:
0 .
With automatic return:
Yes
Cycle time:
5 s
Suitable for:
Cable lugs and connectors
Construction/operation:
Hydraulic compression head
For component:
C-clamps
Compression shape:
Round compression

Battery Crimp Tool


NEMIQ
With locking device (for mechanical tools):
No
Inserts exchangeable:
Yes
Number of included inserts:
1 .
With automatic return:
No
Cycle time:
5 s
Compression force:
60 kN
Suitable for:
Cable lugs and connectors
Construction/operation:
Accumulator-hydraulic
For component:
Non-insulated Cu tube and sheet terminals
Compression shape:
Universal (exchangeable inserts)

Ring terminals PB-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
PC
Colour insulation:
Blue, Yellow, Red, Other
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
V2
UL-File No.:
E44245
Yes
Yes

Ring terminals A-series, 10-35 mm², nylon


NEMIQ Nichifu
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
62-160 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-40-105 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
V2
UL-File No.:
E44245
Yes
Yes
Yes

DINFLEX-Y (LiYY) - Korta längder


NEMIQ -
Number of cores:
2-37 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
16-64.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-CY (LiYCY) - Korta längder


NEMIQ
Number of cores:
2-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
Yes
Protective barrier:
N/A
Armouring/reinforcement:
Braiding
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
Yes, No
Min. permitted bending radius, stationary application/permanent installation:
18.5-76.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

DINFLEX-Y (LiYY) - Korta längder, parttvinnade


NEMIQ
Number of cores:
4-50 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
Yes
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Grey
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-30-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
25.5-62 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

RQ (H05Z-K, H07Z-K) - Box


NEMIQ -
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70-90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300-600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare, Tinned
Halogen free:
Yes
Packaging:
Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
10.4-19 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Blade terminals PB-series SF


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Pin shape
According to DIN:
No
Insulation:
PC
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material:
Copper
Voltage max:
600V
UL-File No.:
E44245
Yes
Yes

Blade terminals PB-series SFB


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Reel/roll packaging:
No
Max. current (Imax):
19-48 A
Flange shape:
Pin shape
According to DIN:
No
Insulation:
PC
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Material:
Copper
Voltage max:
600V
UL-File No.:
E44245
Yes
Yes

R2G4 - 400 m spool 2-colors


NEMIQ -
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-100 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
100 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
100 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Green/yellow, Other, Black/white, Yellow/black, Red/black, Red/Blue, Blue/Brown, Blue/Yellow, Blue/Pink, Blue/Red, Blue/Black, Blue/White, Brown/Orange, Brown/Pink, Brown/Black, Brown/White, Grey/Blue, Grey/Green, Grey/Red, Grey/Black, Grey/White, Green/Red, Green/Black, Green/White, Yellow/Purple, Yellow/Red, Yellow/Violet, Yellow/White, Orange/Black, Orange/White, Pink/Brown, Pink/White, Red/Green, Red/White, Violet/Yellow, White/Violet
Operating temperature:
-40-100 °C
Core colour:
Green/yellow, Several
Conductor surface:
Bare
Packaging:
Reel B3, Reel B5, Reel B6
Min. permitted bending radius, stationary application/permanent installation:
8-14 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

R2G4 - 400 m spool 1-color


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Purple, Pink, Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-100 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
100 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
100 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Pink, Purple
Operating temperature:
-40-100 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare
Packaging:
Reel B6
Min. permitted bending radius, stationary application/permanent installation:
7-14 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Ring terminals on reel, HAB ICTBX-series


NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Max. current (Imax):
19-48 A
Flange shape:
Ring shape
According to DIN:
No
Insulation:
PC
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
No
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
Surface protection:
Tinned
Operating temperature:
-40-125 °C
Material:
Copper
Voltage max:
600V
V2
UL-File No.:
E44245
Yes
Yes
Availability:
No

NEMIQ

Svetskabel - Dubbelisolerad, bobin


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70-80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
43.2-96 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RKUB Single conductor


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
60 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Black/white, Red/black, Blue/Black, Grey/Red, Grey/Black, Green/Black, Yellow/Red
Operating temperature:
-25-70 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, Black and white, White, Several
Conductor surface:
Bare
Packaging:
Ring, Reel B3, Reel B4
Min. permitted bending radius, stationary application/permanent installation:
6.8-47.6 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

NEMIQ
Suitable for Class 2 conductor:
Yes
Suitable for Class 5 conductor:
Yes
Model:
UL model
Max. current (Imax):
19-48 A
Number of branches:
0 N/A
Insulation:
Polyamide (PA)
Colour insulation:
Blue, Yellow, Red
Sleeve form:
Short
Suitable for solid cores:
Yes
Suitable for stranded conductors:
Yes
Suitable for fine strand conductors:
Yes
Suitable for high temperatures (to 650 °C):
No
Suitable for insulated varnish:
No
Suitable for round conductors:
Yes
Suitable for flat conductors:
No
For pull protected connections:
No
Voltage level:
Up to 600 V
Type of connection:
Other
Oil stop/centre bar:
No
Surface protection:
Tinned
Fire classification:
According to UL94V2
Operating temperature:
-40-105 °C
Material:
Copper
Voltage max:
600V
Halogen free:
Yes
Packaging:
Loose piece
V2
Yes