Logged in as:

Show all filters

Hide all filters

  • 1
  • 2
  • 3
  • Total: 70

RQ (H05Z-K, H07Z-K) - Drum


NEMIQ -
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Black
Conductor surface:
Bare
Halogen free:
Yes
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
36.76-63.44 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK Drum


NEMIQ -
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
25.6-60.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

SKUB Tvillingkabel


NEMIQ -
Number of cores:
2 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyvinyl chloride (PVC)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-25-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Red/black, Blue/Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-25-70 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Packaging:
Drum
Min. permitted bending radius, stationary application/permanent installation:
146-330 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK BOX


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Green/yellow
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Green/yellow
Conductor surface:
Bare
Halogen free:
No
Packaging:
Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
15.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Texiline


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Blue, Brown, Grey, Green/yellow, Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
6-14.7 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

H01N2-D FT - Spool


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
58.2-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK (H05V-K, H07V-K)


-
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Red, Light blue, Dark blue
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-5-70 °C
Core colour:
Blue, Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
25.6-60.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Svetskabel - Dubbelisolerad, trumma


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Yellow
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Yellow
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Yellow
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

SYYB


NEMIQ
Number of cores:
2 .
Material core insulation:
Polyurethane (PUR)
Specification core insulation:
Other
Core identification:
Colour
Protective conductor:
No
Material outer sheath:
Polyurethane (PUR)
Specification material outer sheath:
Other
Colour outer sheath:
Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-50-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
Yes
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
70.4-104 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
55-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

H01N2-D FT - Drum


NEMIQ
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-20-80 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Core colour:
Red, Black
Conductor surface:
Tinned
Min. permitted bending radius, stationary application/permanent installation:
66-115.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDOE (H07RN-F) - Drum 500 m


NEMIQ
Number of cores:
3-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Core colour:
Several
Conductor surface:
Bare
Min. permitted bending radius, stationary application/permanent installation:
59.5-87.5 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RK TM - Cable


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Red
Material insulation:
Polyvinyl chloride (PVC)
Designations:
H07V-K (RK 1.5 - 400mm2)
Operating temperature:
-30-70 °C
Core colour:
Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B3
Min. permitted bending radius, stationary application/permanent installation:
38.4-73.8 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

UL 1015


NEMIQ -
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
No
Permitted cable outer temperature after assembling without vibration:
-25-105 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
105 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-105 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
10.2-19.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes
Yes

Kopplingskabel för solceller H1Z2Z2-K - Ring

Kopplingskabel för solceller H1Z2Z2-K - Trumma


NEMIQ
Single insulated/Double insulated:
Double insulated

RQ (H05Z-K, H07Z-K) - Box


NEMIQ -
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70-90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
300-600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Pink, Purple, Light blue, Dark blue
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Pink, Red, Black, White
Conductor surface:
Bare, Tinned
Halogen free:
Yes
Packaging:
Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
10.4-19 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

Svetskabel - Dubbelisolerad, bobin


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
70-80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Reel B5
Min. permitted bending radius, stationary application/permanent installation:
43.2-96 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RQ (H05Z-K, H07Z-K) - Ring


NEMIQ -
Number of cores:
1 .
Material core insulation:
Other
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Grey, Red, Black, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-15-90 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
90 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Grey, Green/yellow, Brown, Red, Light blue
Material insulation:
Polymen
Operating temperature:
-5-90 °C
Core colour:
Blue, Brown, Grey, Green/yellow, Red, Black
Conductor surface:
Bare
Halogen free:
Yes
Packaging:
Ring, Carton (box)
Min. permitted bending radius, stationary application/permanent installation:
25.04-63.44 mm
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

RDO (H05RN-F)


NEMIQ
Number of cores:
2-3 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
500 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
EPDM
Operating temperature:
-25-60 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
33-41 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No

Svetskabel - Dubbelisolerad, ring


NEMIQ
Number of cores:
1 .
Material core insulation:
Polyvinyl chloride (PVC)
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Yellow, Orange, Red, Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-45-70 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
80 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
No
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black, Orange, Yellow, Red
Material insulation:
Polyvinyl chloride (PVC)
Operating temperature:
-40-80 °C
Core colour:
Yellow, Orange, Red, Black
Conductor surface:
Bare
Halogen free:
No
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
43.2-90 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

TX UL 3607


NEMIQ -
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-105 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
105 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
Material insulation:
XLPE
Operating temperature:
-40-105 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Drum, Reel B5
Min. permitted bending radius, stationary application/permanent installation:
7.2-41.7 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes
Yes
Yes

RDOE (H07RN-F) - Spool


NEMIQ
Number of cores:
2-7 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - ethylene propylene rubber (EPR)
Core identification:
Colour
Protective conductor:
Yes, No
Material outer sheath:
Rubber
Specification material outer sheath:
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-30-60 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
60 °C
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
750 V
Halogen free:
No
Conductor category:
Class 5 = flexible
Single insulated/Double insulated:
Double insulated
Colour:
Black
Material insulation:
EPDM
Operating temperature:
-25-60 °C
Core colour:
Several
Conductor surface:
Bare
Halogen free:
No
Min. permitted bending radius, stationary application/permanent installation:
55-111 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
Yes

SIF


NEMIQ -
Number of cores:
1 .
Material core insulation:
Rubber
Specification core insulation:
Rubber - silicone rubber (SIR)
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-60-185 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
185 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Halogen free:
Yes
Conductor category:
Class 6 = very flexible
Single insulated/Double insulated:
Single insulated
Colour:
Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue
Material insulation:
Silicone
Operating temperature:
-40-185 °C
Core colour:
Blue, Brown, Yellow, Grey, Green, Green/yellow, Red, Black, White
Conductor surface:
Tinned
Halogen free:
Yes
Packaging:
Ring
Min. permitted bending radius, stationary application/permanent installation:
7.5-19.2 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
No
Low temperature resistant (according to EN 60811-504+505+506):
No
Oil resistant according to EN IEC 60811-404:
No
  • 1
  • 2
  • 3
  • Total: 70
We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.