Refined by
Hide irrelevant options
Product Category
Product Group
Single insulated/Double insulated
Colour
Nominal cross section conductor
Halogen free
Packaging
Material insulation
Conductor Surface
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Core identification
Flame retardant
Material outer sheath
Conductor category
Protective conductor
Low smoke (according to BS EN 61034-2)
Reaction-to-fire class according to EN 13501-6
AWG size
Show all filters
Hide all filters
TX UL 3746
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin.
Idealisk för installation inuti rör samt för utanpåliggande installation. Mycket goda elektriska och mekaniska egenskaper.
Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan.
Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
Halogenfri.
Uppbyggnad
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation: XHFFR
Mantelfärg: Se produktdata nedan
Tekniska data:
Driftspänning: 300 V
Temp.område: -40ºC till +105ºC
Godkännanden, flambeständighet
IEC60754-1
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-105 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 105 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- XLPE
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Reel B5
- Min. permitted bending radius, stationary application/permanent installation:
- 4.05-6.42 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
Boundary wire for robotic lawn mowers
High quality signal cable for robot lawn mowers of all brands. Resistant and durable PE-insulation cable that can be buried in moist soil or gravel. It has tinned copper conductors for best conductivity and it does not risk corroding at joints.
Cable can be nailed down on lawn or buried underground. Make sure that the grass is cut when using staples. Regardless of the method, the cable will not be visible after a few weeks as it will sink into the lawn.
Length: 50m, 100m, 250m, 500m, 1000m.
Area: See below.
Sheath: PE (Polyethylene)
Outer diameter: 2.5mm
Color: Green
Marking: Meter marked
- Number of cores:
- 1 .
- Material core insulation:
- Other
- Specification core insulation:
- Polyethylene (PE)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Green
- Permitted cable outer temperature after assembling without vibration:
- -40-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Core colour:
- Green
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 8.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 155 - Spools
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Spool HS150, Spool HS151, Spool HS400, Spool HS200, Spool HS600
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-37.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
EN-Cable, Single core conductor
Halogenfria, elektronstråle-tvärlänkade kablar med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyller kraven för EN 50264- 3- 2,EN 50306-4.
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift.
Riktlinjer för val och installation beskrivs i standarderna:
EN 50355 och EN 50343.
RADOX EN 50264- 3- 2 ,EN 50306-4600V MM Flerledarkablar med reducerade väggmått.
Nominell spänning: 600 / 1000 V AC.
Risknivå: MM (extra låg temperatur, extra olja och extra bränslebeständig).
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour, None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- White
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- White
- Material insulation:
- Polyolefin (POE)
- Core colour:
- White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.26-8.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Spool
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS150, Spool HS151, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-20.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX UL3289
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Yellow, Green/yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Purple, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Drum, Spool HS151, Spool HS400, CK, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 7.2-30.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes, No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Drum
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green/yellow, Red
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Drum
- Min. permitted bending radius, stationary application/permanent installation:
- 25.5-73.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Conipack
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
Structure:
Conductor: Tinned stranded copper acc. to IEC 60228 class 5
Conductor insulation: RADOX 125 (polyolefin)
Sheath Colour: See product data below
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Grey, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Grey, Yellow, Brown, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Green/yellow, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- CK
- Min. permitted bending radius, stationary application/permanent installation:
- 6.75 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTOL 155S FLR-A
Vehicle cable that has (FHLR91X According to DIN76722) excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure, temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in hybrid and electric vehicles, trucks, among others.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155S (polyolefin)
Coat color: See product data.
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage AC: <
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 3 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Green, Orange, Red, Black, White
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -40-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes, No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated, Double insulated
- Colour:
- Black, Green, Orange, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Green, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes, No
- Packaging:
- CK2
- Min. permitted bending radius, stationary application/permanent installation:
- 4.5-6.9 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 155 - Conipack
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Black
- Flame retardant:
- No
- Conductor material:
- Copper
- Twisted cores:
- No
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Brown, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Black
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- CK
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 4 GKW-AX/S 1800/3000 V - multi conductor
Halogenfri skärmad dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Skärm: Förtent kopparfläta. Täckningsgrad c:a 85%.
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 4 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Low smoke (according to EN 61034-2):
- Yes
RADOX 4 GKW-AX 1800/3000 V M J - Single conductor
Halogenfri dubbelisolerad flexibel kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 2 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Colour:
- Black
- Halogen free:
- Yes
RADOX 4 GKW-AX/S 1800/3000 V - Single core conductor
Halogenfri skärmad dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Skärm: Förtent kopparfläta. Täckningsgrad c:a 85%.
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Drum
- Low smoke (according to EN 61034-2):
- Yes
RADOX 9 GKW-AX 3600/6000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 3.6/6.0 kV AC, 4.5/9.0 kV DC
Provspänning: 12 kV (50 Hz, 15 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet:
BS 6853
DIN 5510
NF F16-101
BS 4066-3,
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1,
EN 50265-2-1 IEC 60332-3-24,
EN 50266-2-4 IEC 60754-1,
EN 50267-2-1 IEC 60754-2,
EN 50267-2-3 IEC 61034-2,
EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3600 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS401
- Low smoke (according to EN 61034-2):
- Yes
RADOX GKW-LW - Single core conductor
Halogenfri dubbel isolerad, tunn väggisolering, polymer med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyller kraven för EN 50306-2.
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift.
Riktlinjer för val och installation beskrivs i standarderna:
EN 50355 och EN 50343.
Nominell spänning: 600 / 1000 V AC.
- Colour outer sheath:
- White
- Colour:
- White
- Halogen free:
- Yes
- Packaging:
- Spool HS200
RADOX GKW-LW/S EMC
Halogenfri skärmad styrkabel för skyddad fast förläggning i tågapplikationer.
Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen. Användningsområden är styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Skärmflätan av förtent koppar skärmar den inre strömkretsen mot omgivningen samt ger ett extra mekaniskt skydd. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW P/ GKW HP (polyolefin-copolymer)
Ledarfärg: Vita, numrerade
Skärm: Förtent kopparfläta.
Täckningsgrad c:a 85%. Transparant plastfolie
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 600/1000 V AC, 750/1500 V DC
Provspänning: 3500 V (50 Hz, 5 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265-2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-20 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1500 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Low smoke (according to EN 61034-2):
- Yes
RADOX TENUIS -TW 600V MM S
Halogenfri skärmad styrkabel för skyddad fast förläggning i tågapplikationer. Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen, mindre, lättare och mer flexibel än tidigare kablar för järnvägsapplikation.
Användningsområden:
Styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Riktlinjer för val och installation beskrivs i standarderna EN 50355 och EN 50343. Tålig mot hög mekanisk belastning, olja och bränsle.
Skärmflätan av förtent koppar skärmar den inre strömkretsen mot omgivningen samt ger ett extra mekaniskt skydd. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX EI 303 (polyolefin-copolymer) Ledarfärg: Vita, numrerade samt g = grön/gul .
Skärm: Förtent kopparfläta
Täckningsgrad c:a 85%.Transparant plastfolie
Ledarisolation yttermantel: RADOX EM 104 (polyolefin-copolymer)
Mantelfärg: Svart med gul text
Tekniska data:
Driftspänning: 600/1000 V AC, 750/1500 V DC
Provspänning: 3500 V (50 Hz, 5 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden:
EN 50355 samt EN 50343, flambeständighet
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265-2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-6 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX TENUIS -TW 600V MM
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces, smaller, lighter and more flexible than previous cables for railway application.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Guidelines for selection and installation are described in the standards EN 50355 and EN 50343. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX EI 303 (polyolefin copolymer)
Conductor color: White, numbered and g = green / yellow. Transparent plastic foil
Conductor insulation outer sheath: RADOX EM 104 (polyolefin copolymer)
Sheath color: Black with yellow text
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals:
EN 50355 and EN 50343, flame resistance
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-12 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX 155 - Industribobin
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Grey, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, Green/yellow, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Grey, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-10.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3271
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Drum, Spool HS400, Spool HS401
- Min. permitted bending radius, stationary application/permanent installation:
- 7.8-33.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 1 .
RADOX UL3266
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS151, Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 3.96-7.23 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 4 GKW-AX 1800/3000 V - Single conductor
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS401
- Low smoke (according to EN 61034-2):
- Yes