Refined by
Hide irrelevant options
Produktgrupp
Show all filters
Hide all filters
COAXIAL CONNECTOR, SMA, 50 Ohm, Straight bulkhead cable
Coaxial_Connector_SMA_50Ohm_Straight_bulkhead2_vp
- Type of connector:
- SMA
- Model:
- Plug/plug
- Suitable cable:
- EZ-86-TP-M17, MULTIFLEX-86, SUCOFORM-86
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Type of connector:
- Other
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Type of connector:
- BNC
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Type of connector:
- BNC
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
RADOX TENUIS -TW 600V MM
80049
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces, smaller, lighter and more flexible than previous cables for railway application.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Guidelines for selection and installation are described in the standards EN 50355 and EN 50343. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX EI 303 (polyolefin copolymer)
Conductor color: White, numbered and g = green / yellow. Transparent plastic foil
Conductor insulation outer sheath: RADOX EM 104 (polyolefin copolymer)
Sheath color: Black with yellow text
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals:
EN 50355 and EN 50343, flame resistance
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-12 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX 125 Multi conductor unscreened
140201
Halogen-free cable suitable both for fixed installation or as a connection cable in dry, damp and wet areas both indoors and outdoors.
Due to the good mechanical properties and the high chemical resistance, RADOX 125 is especially suitable in industry in demanding environments, eg for machines and industrial equipment.
- Number of cores:
- 2-27 .
- Protective conductor:
- No
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 1000 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125B Multi conductor screened
140301
Halogenfri kabel lämpligt både för fast förläggning eller som anslutningskabel i torra, fuktiga och våta utrymmen både inom- och utomhus.
Med hänsyn av de goda mekaniska egenskaper samt den höga kemikaliebeständigheten, är RADOX 125 speciellt lämplig inom industrin i krävande miljöer, t.ex för maskiner och industriutrustningar. Kabeln har flätad kopparskärm med hög täckningsgrad, därför är den mycket lämplig i miljöer med hög störningsnivå (enligt EMC-direktivet).
- Number of cores:
- 2-12 .
- Protective conductor:
- No
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Nominal voltage:
- 1000 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
RXL 125 S2
RXL 125 S2
Halogen-free cable suitable both for fixed installation or as a connection cable in dry, damp and wet areas both indoors and outdoors.
Due to the good mechanical properties and the high chemical resistance, RADOX 125 is especially suitable in industry in demanding environments, eg for machines and industrial equipment.
- Number of cores:
- 4-16 .
- Protective conductor:
- No
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Nominal voltage:
- 1000 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Availability:
-
No
- Type of connector:
- Other
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
Yes
- Type of connector:
- 7/16
- Model:
- Plug/plug
- Suitable cable:
- GX-07272-D, RADOX-RF-214, RG-214-/U
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Type of connector:
- 7/16
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Type of connector:
- N
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Type of connector:
- SMA
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
Yes
- Type of connector:
- 7/16
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
No
- Type of connector:
- SMA
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
- Availability:
-
Yes
- Type of connector:
- N
- Model:
- Plug/plug
- Impedance:
- 50 Ohm
- Construction type:
- Straight
RADOX 155 - Industribobin
Radox_155_Industribobin_vp
Flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Grey, Red, Black, White, Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -55-155 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 155 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, Green/yellow, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -55-155 °C
- Core colour:
- Blue, Grey, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-10.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No