Refined by
Hide irrelevant options
Produktgrupp
Show all filters
Hide all filters
RADOX 3271
141901
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Core colour:
- Blue, Brown, Grey, Green, Green/yellow, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- No
- Packaging:
- Drum, Spool HS400, Spool HS401
- Min. permitted bending radius, stationary application/permanent installation:
- 7.8-33.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 1 .
RADOX UL3266
141801
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Green, Grey, Orange, Yellow, Brown, Red, White, Blue, Purple
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Purple, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS151, Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 3.96-7.23 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 4 GKW-AX 1800/3000 V - Single conductor
140901
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 1 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1800 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS401
- Low smoke (according to EN 61034-2):
- Yes
RADOX MARIN MFH-S B
80046
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 3 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 17.25 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX MARIN MFH-S B, Twisted pair
Radox_Marin_MFH_S_B_Partvinnad
Very flexible more conductor cable for fixed and free installations of power, control and lighting applications in harsh environments such as diesel engines, ship oil platforms and other offshore units.
Resistant to oil and drill bits according to NEK TS 606
The flexibility of the cables makes installation safe and easy.
Especially in small areas that are connection points for gears and motors.
The outer casing of the cable is specially designed to give small mechanical forces when you pull the cable and at the same time maintain the mechanical properties of the insulation.
- Number of cores:
- 8-28 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 31.5-42.3 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 125 - Industry Spool
RADOX_125_Industribobin_vp
Halogen free flexible connector cable for the internal wiring in lamps, heaters, electrical equipment, command and control cabinets, and in the construction industry. Ideal for the installation inside the tubes as well as for external installation.
Very good electrical and mechanical properties. Wide temperature range and high resistance to oils, ozone, hydrolysis and mechanical stress. Connection wire is flame retardant, at fire it develops minimum of smoke and no corrosive gases are released.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Brown, Yellow, Grey, Green, Orange, Red, Black, White, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -55-145 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Black, Green, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-125 °C
- Core colour:
- Blue, Brown, Yellow, Grey, Green, Green/yellow, Orange, Red, Black, White
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS150, Spool HS400, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 4.35-10.05 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTOL 155 TAPE
RADOX_AUTOL_P_TAPE
Batterikabel som har (FHLR91X Enligt DIN76722) utmärkt beständighet mot hög och låg temperatur, ozon- och väderbeständighet, beständig mot högt tryck, temperatur, motorolja, bränslen och hydrolys, flamskyddsmedel, hög nötningsbeständig, lödbeständig, lätt att skala och bearbeta tack vare tape, enligt ISO 6722 klass D, LV 112, ISO 14572, LV 212, DIN 76722.
Uppfyller EU - direktiv 2000/53 / EG om uttjänta fordon. Det är fritt från bly, kvicksilver, kadmium och krom VI.
Användning: Lågspänningskabel, för användning i bla hybrid- och elfordon, lastbilar.
FÖRSIKTIGHET: Särskild försiktighet ska iakttas för kablar som används med spänningar över 60 VDC för att skydda dem från mekanisk belastning för att undvika stötar (ISO 6722: 2006)
Ledare: Glödgad koppar enligt ISO C flexibel 6
Ledarisolation: 155S (polyolefin) Mantelfärg: Se produktdata.
Tekniska data:
Driftspänning: 1000VAC 1500VDC
Provspänning AC: < Temp. område: -40ºC till +150ºC (3000H)
Minsta böjradie: 3 x kabelns diameter
Godkännanden, Standarder: ISO 6722 class D iSO 19642-9
- Colour outer sheath:
- Red
- Single insulated/Double insulated:
- Single insulated
- Colour:
- Red
- Halogen free:
- Yes
RADOX 3 GKW 600/1000 V - Single conductor
140801
Halogenfri kopplingskabel för fast förläggning i tågapplikationer, lamparmaturer, elektriska applikationer samt kabeldragning i vagnar, terminaler och annan kraftförsörjningsapparatur. Tålig mot hög mekanisk belastning, olja och bränsle.
- Number of cores:
- 1 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Blue, Grey, Red, Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, Green/yellow, Red, Blue
- Material insulation:
- Polyolefin (POE)
- Operating temperature:
- -40-120 °C
- Core colour:
- Blue, Grey, Green/yellow, Red, Black
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Packaging:
- Spool HS400, Spool HS401, CK, Spool HS200
- Min. permitted bending radius, stationary application/permanent installation:
- 6-53.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Type of connector:
- BNC
- Model:
- Plug/plug
- Suitable cable:
- 142B/U, 223/U, 400/U, ASNE0293 XF, ENVIROFLEX-142, G-03130-HT, G-03232-D-01, GX-03272, GX-04273, RG-223/U, RG-58C/U, RG-59B/U
- Impedance:
- 50-75 Ohm
- Construction type:
- Straight