Refined by
Hide irrelevant options
Product Category
Product Group
Colour
Nominal cross section conductor
Halogen free
Packaging
Material insulation
Conductor Surface
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Screen
Core identification
Flame retardant
Material outer sheath
Conductor category
Protective conductor
Low smoke (according to BS EN 61034-2)
Reaction-to-fire class according to EN 13501-6
Armouring/reinforcement
Twisted cores
Show all filters
Hide all filters
RKK (H05VV-F)
Rund anslutningskabel för normal drift, t ex i bostäder, kök och kontor; även i fuktiga lokaler för anslutning av t ex tvättmaskiner, torktumlare och kylskåp. Olämplig för permanent utomhusanvändning, eller där risk för skador p g a värme föreligger.
Uppbyggnad Ledare: Extra mångtrådig koppar enligt IEC 60228 klass 5
Ledarisolation: Blyfri PVC
Mantelfärg: Vit eller grå blyfri PVC
Tekniska data:
Märkspänning Uo/U: 300/500 V
Partmärkning:
2-ledare: Blå, brun
3-ledare: Grön/gul, blå, brun
4-ledare: Grön/gul, brun, svart, grå
5-ledare: Grön/gul, blå, brun, svart, grå
Temperaturområde: I kontinuerlig drift max. ledartemperatur 60ºC. Lägsta hanteringstemperatur +5ºC
Minsta böjradie: 6 x kabelns diameter, utan belastning
- Number of cores:
- 3 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- No
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- White
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 49.5-61.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Trumma
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 30.4-153.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIFF, Silikonkabel
Silikon-mantlade flerledarkabel erbjuder elingenjörer och elektriker ett fantastiskt utbud av alternativ.
Perfekt för höga eller låga temperaturer kommer dessa kablar fungera utmärkt mellan -50ºC och 180ºC.
Vid brand producerar de minimal rök och kan användas till installation i offentliga byggnader.
Uppbyggnad Ledare: Fintrådig ledare av förtent koppar.
Ledarisolering: Silikonbas.
Ledarisolation: Ledarna tvinnade i lager.
Yttermantel: Silikonbas.
Mantelfärg: Grå.
Flamhämmande.
Tekniska data:
Driftspänning: 300/500 V
Provspänning: 2000 V
Temperaturområde: -50ºC till +180ºC
Minsta böjradie: Flexibel: 12 x kabeldiametern Fast: 4 x kabeldiametern
Godkännanden, Flambeständighet
VDE 0295. VDE 0293. VDE 0293-308. IEC 60332-1-2 (F2)
- Number of cores:
- 2 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Grey
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -60-180 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 180 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Silicone
- Core colour:
- Grey
- Conductor surface:
- Tinned
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 25.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX - PUR/PUR 2000, 2001
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabelytterdiameter, höga mekaniska påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. För installation på fordon för skog, gräv och industriella maskiner och maskinverktyg.
Uppbyggnad Ledare: Blank flertrådig koppar klass 6.
Ledarisolation: PUR
Ledarfärg - 2001: Svart med vit nummermärkning
Ledarfärg - 2000: Färgade ledare
Skyddsledare: G = Grön/gul, X = Utan skyddsledare
Yttermantel: PUR
Mantelfärg: Svart
UV-beständig
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Temp. område: Fast förläggning min/max: -50ºC till +80ºC
Rörlig förläggning min/max: -40ºC till +80ºC
Minsta böjradie: Flexibel: 15 x kabeldiametern
Oljebeständighet: God
Godkännanden: CE
- Number of cores:
- 2-7 .
- Nominal voltage:
- 300 V
- Colour:
- Black
- Material insulation:
- Polyurethane (PUR)
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Number of cores:
- 2-8 .
- Nominal voltage:
- 250 V
- Colour:
- Black
- Material insulation:
- EPDM, Polyurethane (PUR), TPE
- Conductor surface:
- Bare
- Halogen free:
- No
NELCOFLEX-CY, SERVO
Flexibel kabel för användning till servomotorsystem från ledande tillverkare.Kombination av ledare för kraft och signalöverföring. Termoskydd och bromsskydd kan t.ex. integreras med kraftmatningen. Längre ledningsdragningar är möjliga tack vare en design med låg kapacitans. Utrymmes- och viktbesparande installationer tack vare liten kabeldiameter. Skärm av flätad koppar skyddar kabeln mot elektromagnetiska störningar.
EMC-kompatibel anslutning mellan frekvensomriktare och frekvensomformare för normala krav i dragkedjeapplikationer, rörliga drivsystem, inom robotteknik och tillverkningsanläggningar. Lämplig för användning i torra och fuktiga rum.
Uppbyggnad
Ledare: Blank flertrådig koppar cl.6
Ledarisolation: PELON®2
Ledarfärg: Svart med vit nummermärkning. Gröngul skyddsledare
Innermantel: PVC
Skärm: Fleece och flätad koppartråd
Yttermantel: PVC
Mantelfärg: Orange eller Grå
Teknisk data:
Märkspänning: Uo/U0,6/1kV
Märkspänning: Uo/U enligt UL/CSA600/1000V
Provspänning: 4kV
Kabelarea: 0.5mm²-16mm²
Temp. område: Fast förläggning min/max: -30ºC till +80ºC
Rörlig förläggning min/max: -5ºC till +80ºC
Ledarmotstånd vid +20°C enl. till IEC 60228 cl. 6
Isolationsmotstånd vid 20° C ≥ 20 G Ohm x km
Minsta böjradie: 5 x kabelns diameter fast förlagd
10x kabels diameter rörligt förlagd
Oljebeständighet: Enl: ISO 6722, EN 60811-404 (endast mineral olja)
Flambeständighet: Självsläckande och flamskyddande enl. till IEC 60332-1; UL: VW1; CSA: FT1.
Godkännanden: Uppfyller svensk och europeisk standard enligt SS EN 60204 UL/CSA.
- Number of cores:
- 4 .
- Nominal voltage:
- 1000 V
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Conductor surface:
- Bare
- Halogen free:
- No
- Availability:
-
Yes
- Number of cores:
- 5 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare, Tinned
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 86 mm
- Approved according to SS EN 60204:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
MULTINORM-Y
HAR/UL-CSA styrkablar är särskilt lämpliga för exportinriktad tillverkning av maskiner, anläggningar och utrustning; på grund av de internationella godkännandena kan dessa styrkablar nästan användas över hela världen. De installeras i torra och fuktiga rum med medelstor mekanisk påfrestning och som anslutningskablar för statiska och icke-kontinuerliga böjningsapplikationer. Dessa kablar är dessutom extremt flexibla och används därför för värme- och kylinstallationer men inte utomhus eller för direkt nedgrävning.
Produkten motsvarar direktivet 2014/35/EU (lågspänningsdirektivet).
Uppbyggnad
Ledare: Blank flertrådig koppar class 5
Ledarisolation: Pvc
Ledarfärg: Svart med vit nummermärkning. Gröngul skyddsledare
Yttermantel: Pvc
Mantelfärg: Grå
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm²-70mm²
Temp. område: Fast förläggning min/max: 5ºC till +70ºC
Temp. område: UL+CSA: 5ºC till +90ºC
Isolationsmotstånd: > 20 MΩ x km
Minsta böjradie: 12,5 x kabelns diameter
Godkännanden:
Cpr klass: Eca
Självsläckande och flamskyddsmedel enl. till IEC
60332-1; VW1; CSA FT1
Standard EN 50525-2-51 / VDE 0285-525-2-51; UL style
2517/2587 och CSA C22.2 nr. 210.2-M90 AWM I A/B II
A/B
Standard EN 50525-2-51 / VDE 0285-525-2-51; UL stil
2517/2587 och CSA C22.2 nr. 210.2-M90 AWM I A/B II
A/B
Godkännande: HAR: 300/500 V - 70 ° C | UL / CSA 600 V - 90 ° C
- Number of cores:
- 3-5 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 32.4-40.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-Y
Flexible oil resistant cable is resistant to the effects of chemicals and acids.
The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Color-coded conductors. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation
Best: 8 x 107 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500-1000 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 19.6-164.8 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Korta längder
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 31.6-105.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX - PUR
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabelytterdiameter, höga mekaniska påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. Lämplig för användning i kabelkedjor och kontinuerligt rörliga maskiner samt
portalrobotar.
Uppbyggnad:
Ledare: Blank flertrådig koppar klass 6.
Ledarisolation: PP
Yttermantel: PUR, PURWIL
Mantelfärg: Grå, Orange
Ledarfärg - PUR: Svart med vit eller svart nummermärkning.
Ledarfärg - PURWIL: Färgade ledare enl. HD 308
Gröngul skyddsledare.
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm² -70mm²
Temp. område: Fast förläggning min/max: -40ºC till +90ºC
Rörlig förläggning min/max: -40ºC till +90ºC
Minsta böjradie: 5 x kabelns diameter
Oljebeständighet: God
Flambeständighet: IEC 332-1
Godkännanden: DIN EN 60811-404
VDE 0482 del 332-2-2 resp. IEC 60332-2-2
Tillämpade standarder: liknande VDE 0250
- Number of cores:
- 2-25 .
- Material core insulation:
- Rubber, Polyurethane (PUR)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyurethane (PUR)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Grey, Orange
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60-90 °C
- Screen:
- No
- Armouring/reinforcement:
- Braiding, None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey, Orange
- Material insulation:
- Polyurethane (PUR)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 27.5-97 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY, 0.6/1Kv
Flexibel oljebeständig kabel med god beständighet mot inverkan av kemikalier, syror och lutar. Den fintrådiga uppbyggnaden i kombination med PVC-manteln ger en mycket elastisk kabel.
Kabeln är försedd med en skärm av förtent flätad koppartråd, som skyddar mot mekanisk belastning och framförallt avskärmar elektriska störningar såväl inom som utanför kabeln (EMC-direktivet).
Kabeln används som styr- och manöverkabel på och i industrimaskiner, i kyl- och ventilationsanläggningar.
Kabeln kan användas både inne och utomhus vid beaktan av temperaturområde. Vid förläggning i mark skall kabelskyddsrör användas.
Märkspänning: Uo/U 0,6/1kV
Ledaruppbyggnad: Klass 5 = mångtrådig blank koppar
Ledarisolering: PVC
Ledarfärg/Ledarmärkning: Svart med vit nummermärkning. Skydds ledare Grön/Gul
Innermantel: PVC svart
Skärm: Fläta av förtent koppartråd
Yttermantel: PVC svart
Böjradie vid fast förläggning: 20 x kabeldiametern
Min temperatur vid fast förläggning: -30°C
Max temperatur vid fast förläggning: +70°C
Min temperatur vid rörlig förläggning: -15°C
Max temperatur vid rörlig förläggning: +70°C
Provspänning: 4000V
Brandspridningsklass: IEC 60 332-1 (F2)
Tillverkningsnorm: VDE 0295, IEC 60228
Godkännande enl. EN 50525-2 51
- Number of cores:
- 12 .
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyvinyl chloride (PVC)
- Conductor surface:
- Bare
- Halogen free:
- No
NELCOFLEX-H
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius.
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 VTest voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range:
Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Other
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Other
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- TPE
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 21.2-56 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
SIHF, Silikonkabel
Silikon-mantlade flerledarkablar erbjuder elingenjörer och elektriker ett fantastiskt utbud av alternativ.
Perfekt för höga eller låga temperaturer kommer dessa kablar fungera utmärkt mellan -50ºC och 180ºC.
Vid brand producerar de minimal rök och kan användas till installataion i offentliga byggnader.
Uppbyggnad
Ledare: Fintrådig ledare av förtent koppar.
Ledarisolering: Silikonbas.
Ledarisolation: Ledarna färgmärkta tvinnade i lager.
Yttermantel: Silikonbas.
Mantelfärg: Röd-Brun.
Flamhämmande.
Tekniska data:
Driftspänning: 300/500 V
Provspänning: 2000 V
Temperaturområde: -50ºC till +180ºC
Minsta böjradie:
Flexibel: 12 x kabeldiametern
Fast: 4 x kabeldiametern
Godkännanden, Flambeständighet VDE 0295.VDE 0293.VDE 0293-308IEC 60332-1-2 (F2)
- Number of cores:
- 2-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - silicone rubber (SIR)
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -60-180 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 180 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes, No
- Conductor category:
- Class 5 = flexible
- Colour:
- Brown/Red
- Material insulation:
- Silicone
- Core colour:
- Red, Several
- Conductor surface:
- Tinned
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 25.6-88 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 3 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 3 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 7 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 5 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 5 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- No
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 2 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 3 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Availability:
-
No
- Number of cores:
- 5 .
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Conductor category:
- Class 5 = flexible
- Conductor surface:
- Tinned
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A