Refined by
Hide irrelevant options
Product Category
Product Group
Colour
Nominal cross section conductor
Halogen free
Packaging
Material insulation
Conductor Surface
Core insulation material
Halogen free (according to EN 60754-1/2)
Core colour
Colour outer sheath
Screen
Core identification
Flame retardant
Material outer sheath
Conductor category
Protective conductor
Low smoke (according to BS EN 61034-2)
Reaction-to-fire class according to EN 13501-6
Armouring/reinforcement
Twisted cores
Show all filters
Hide all filters
RDO (H05RN-F)
H05RN-FConnection cable of rubber for use in power tools and light engineering equipment, which means high mechanical stresses occur, in both dry and humid rooms, even outdoors.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H05RN-F: 300/500V
Test voltage: H05RN-F: 2000V
Insulation Resistance > 1 Gohma x cm
Core identification H05RN-F:
2-conductor: blue, brown
3conductor: Green / yellow, blue, brown
4-conductor Green / yellow, brown, black, gray
5-conductor Green / yellow, blue, brown, black, gray
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-3 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -25-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- EPDM
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 33-41 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY - PUR
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabelytterdiameter, höga mekaniska påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. Lämplig för användning i kabelkedjor och kontinuerligt rörliga maskiner samt portalrobotar.
Uppbyggnad:
Uppbyggnad Ledare: Blank flertrådig koppar cl.6
Ledarisolation: PELON®2
Ledarfärg: Svart med vit nummermärkning. Gröngul skyddsledare
Skärm: Fleece och flätad koppartråd
Ledare: Blank flertrådig koppar klass 6.
Ledarisolation: PP
Ledarfärg - PUR: Svart eller vit med vit eller svart
nummermärkning. G=Gröngul skyddsledare. X=Nummermärkt
Ledarfärg - PURWIL: Färgade ledare enl. HD 308
Gröngul skyddsledare
Ledarfärg - Partvinnade: DIN47100
Yttermantel: PUR, PURWIL
Mantelfärg: Grå
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm²-70mm²
Temp. område: Fast förläggning min/max: -40ºC till +90ºC
Rörlig förläggning min/max: -40ºC till +90ºC
Minsta böjradie: 5 x kabelns diameter
Oljebeständighet: God
Flambeständighet: IEC 332-1
Godkännanden: DIN EN 60811-404
VDE 0482 del 332-2-2 resp. IEC 60332-2-2
Tillämpade standarder: liknande VDE 0250
- Number of cores:
- 4-20 .
- Material core insulation:
- Polyurethane (PUR)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyurethane (PUR)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Grey
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 90 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 6 = very flexible
- Colour:
- Grey
- Material insulation:
- Polyurethane (PUR)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 111 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY, SERVO
Flexibel kabel för användning till servomotorsystem från ledande tillverkare.Kombination av ledare för kraft och signalöverföring. Termoskydd och bromsskydd kan t.ex. integreras med kraftmatningen. Längre ledningsdragningar är möjliga tack vare en design med låg kapacitans. Utrymmes- och viktbesparande installationer tack vare liten kabeldiameter. Skärm av flätad koppar skyddar kabeln mot elektromagnetiska störningar.
EMC-kompatibel anslutning mellan frekvensomriktare och frekvensomformare för normala krav i dragkedjeapplikationer, rörliga drivsystem, inom robotteknik och tillverkningsanläggningar. Lämplig för användning i torra och fuktiga rum.
Uppbyggnad
Ledare: Blank flertrådig koppar cl.6
Ledarisolation: PELON®2
Ledarfärg: Svart med vit nummermärkning. Gröngul skyddsledare
Innermantel: PVC
Skärm: Fleece och flätad koppartråd
Yttermantel: PVC
Mantelfärg: Orange eller Grå
Teknisk data:
Märkspänning: Uo/U0,6/1kV
Märkspänning: Uo/U enligt UL/CSA600/1000V
Provspänning: 4kV
Kabelarea: 0.5mm²-16mm²
Temp. område: Fast förläggning min/max: -30ºC till +80ºC
Rörlig förläggning min/max: -5ºC till +80ºC
Ledarmotstånd vid +20°C enl. till IEC 60228 cl. 6
Isolationsmotstånd vid 20° C ≥ 20 G Ohm x km
Minsta böjradie: 5 x kabelns diameter fast förlagd
10x kabels diameter rörligt förlagd
Oljebeständighet: Enl: ISO 6722, EN 60811-404 (endast mineral olja)
Flambeständighet: Självsläckande och flamskyddande enl. till IEC 60332-1; UL: VW1; CSA: FT1.
Godkännanden: Uppfyller svensk och europeisk standard enligt SS EN 60204 UL/CSA.
- Number of cores:
- 4 .
- Nominal voltage:
- 1000 V
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Conductor surface:
- Bare
- Halogen free:
- No
NELCOFLEX ROBOT PUR-Y
ALLMÄNT
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabel ytterdiameter, hög mekanisk påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. Lämplig för användning i kabelkedjor och kontinuerligt rörliga maskiner samt
portalrobotar. En speciell kabelkonstruktion och högkvalitativa komponenter gör att kabeln klarar hög böjradie och torsionscykler under en lång livslängd. UV-Resistent.
Uppbyggnad:
Ledare: Blank flertrådig koppar class 6
Ledarisolation: TPE
Ledarfärg: Svart el vit med vit el svart nummermärkning. Gröngul skyddsledare
Yttermantel: PUR
Mantelfärg: Svart
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm²-70mm²
Temp. område:
Fast förläggning min/max: -40ºC till +80ºC
Rörlig förläggning min/max: -40ºC till +80ºC
Rörligt förlagd böjradie: 10 x kabelns diameter
Fast förlagd böjradie: 7,5 x kabelns diameter
Isolationsmotstånd: min. 100 MOhm x km
Torsions vinkel: max. ± 360°/m
Oljebeständighet: God
Flambeständighet: IEC 332-1
Godkännanden: DIN EN 60332-1-2 VDE 0482 part 332-1-2:2005-06
Tillämpade standarder: liknande VDE 0250
NELCOFLEX - PUR
Den fintrådiga uppbyggnaden i kombination med PUR-manteln ger en mycket elastisk kabel med liten böjradie. Ytterhöljet av polyuretan möjliggör en mycket liten kabelytterdiameter, höga mekaniska påfrestningar kan motstås. Kabeln är nötningssäker, mikrobeständig och flamsäker. Lämplig för användning i kabelkedjor och kontinuerligt rörliga maskiner samt
portalrobotar.
Uppbyggnad:
Ledare: Blank flertrådig koppar klass 6.
Ledarisolation: PP
Yttermantel: PUR, PURWIL
Mantelfärg: Grå, Orange
Ledarfärg - PUR: Svart med vit eller svart nummermärkning.
Ledarfärg - PURWIL: Färgade ledare enl. HD 308
Gröngul skyddsledare.
Teknisk data:
Driftspänning: 300/500 V
Provspänning: 3000 V
Kabelarea: 0.5mm² -70mm²
Temp. område: Fast förläggning min/max: -40ºC till +90ºC
Rörlig förläggning min/max: -40ºC till +90ºC
Minsta böjradie: 5 x kabelns diameter
Oljebeständighet: God
Flambeständighet: IEC 332-1
Godkännanden: DIN EN 60811-404
VDE 0482 del 332-2-2 resp. IEC 60332-2-2
Tillämpade standarder: liknande VDE 0250
- Number of cores:
- 2-25 .
- Material core insulation:
- Rubber, Polyurethane (PUR)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyurethane (PUR)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Grey, Orange
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-90 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60-90 °C
- Screen:
- No
- Armouring/reinforcement:
- Braiding, None
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey, Orange
- Material insulation:
- Polyurethane (PUR)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 27.5-97 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY, 0.6/1Kv
Flexibel oljebeständig kabel med god beständighet mot inverkan av kemikalier, syror och lutar. Den fintrådiga uppbyggnaden i kombination med PVC-manteln ger en mycket elastisk kabel.
Kabeln är försedd med en skärm av förtent flätad koppartråd, som skyddar mot mekanisk belastning och framförallt avskärmar elektriska störningar såväl inom som utanför kabeln (EMC-direktivet).
Kabeln används som styr- och manöverkabel på och i industrimaskiner, i kyl- och ventilationsanläggningar.
Kabeln kan användas både inne och utomhus vid beaktan av temperaturområde. Vid förläggning i mark skall kabelskyddsrör användas.
Märkspänning: Uo/U 0,6/1kV
Ledaruppbyggnad: Klass 5 = mångtrådig blank koppar
Ledarisolering: PVC
Ledarfärg/Ledarmärkning: Svart med vit nummermärkning. Skydds ledare Grön/Gul
Innermantel: PVC svart
Skärm: Fläta av förtent koppartråd
Yttermantel: PVC svart
Böjradie vid fast förläggning: 20 x kabeldiametern
Min temperatur vid fast förläggning: -30°C
Max temperatur vid fast förläggning: +70°C
Min temperatur vid rörlig förläggning: -15°C
Max temperatur vid rörlig förläggning: +70°C
Provspänning: 4000V
Brandspridningsklass: IEC 60 332-1 (F2)
Tillverkningsnorm: VDE 0295, IEC 60228
Godkännande enl. EN 50525-2 51
- Number of cores:
- 12 .
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyvinyl chloride (PVC)
- Conductor surface:
- Bare
- Halogen free:
- No
RDOE (H07RN-F) - Drum
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage:H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 55-87.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - 100m
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 3-25 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 31.6-66.4 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-Y
Flexible oil resistant cable is resistant to the effects of chemicals and acids.
The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Color-coded conductors. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation
Best: 8 x 107 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour, Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500-1000 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 19.6-164.8 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Number of cores:
- 5 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare, Tinned
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 86 mm
- Approved according to SS EN 60204:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Trumma
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 30.4-153.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RDOE (H07RN-F) - Drum 500 m
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Packaging: Drum
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage:H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 3-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Core colour:
- Several
- Conductor surface:
- Bare
- Min. permitted bending radius, stationary application/permanent installation:
- 59.5-87.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RDOE (H07RN-F) - Spool
H07RN-F Connection cable of rubber for use in heavy equipment and farm machinery, where high mechanical stresses occur, in both dry and humid areas, both outdoors and in water.
Structure:
Conductors: Extra stranded copper according to IEC 60228 class 5
Conductor Insulation: EPDM rubber
Sheath Colour: Black
Technical data:
Rated voltage Uo / U:H07RN-F: 450/750V
Test voltage: H07RN-F: 2500V
Insulation Resistance: > 1 Gohma x cm
Core identification H07RN-F:
2-conductor: blue, brown
3-conductor: Green / yellow, blue, brown
4-conductor: Green / yellow, brown, black, gray
5-conductor: Green / yellow, blue, brown, black, gray
7-conductor: sv"1", sv"2", sv"3", sv"4", sv"5", sv"6", green/yellow
Temperature range: Flexible -25ºC to +60ºC (-13ºF to +140ºF)
Minimum bend radius: Flexible 6 x cable diameter
- Number of cores:
- 2-7 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Rubber - ethylene propylene rubber (EPR)
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Rubber
- Specification material outer sheath:
- Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-60 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 60 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Drain wire:
- No
- Nominal voltage:
- 750 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Black
- Material insulation:
- EPDM
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 55-111 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-CY (EMC) - Korta längder
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned braided copper wire, which protects against mechanical loads and in particular all shields electrical freqvencly as well inside and outside the cable (EMC Directive).
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems.
Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Inner Sheath: PVC
Screen: Tinned copper braid
Outer Sheath: PVC
Sheath Colour: Transparent
Technical data:
Rating voltage: 300/500 V
Test voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range: Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1
Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-50 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Transparent
- Material insulation:
- Polyvinyl chloride (PVC)
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 31.6-105.6 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
NELCOFLEX-H
Flexible oil resistant cable is resistant to the effects of chemicals and acids. The finely stranded structure in combination with PVC sheath provides a very flexible cable with a small bending radius.
It is used as command and control cable, and in industrial machinery, in cooling and ventilation as well as in computer and signal systems. Can be used in dry and wet areas.
Structure
Conductor: Blank stranded copper
Conductor insulation: PVC
Conductor identification: Black with white numbers mark. Green-yellow protective conductors
Outer Sheath: PVC
Sheath Colour: Grey
Technical data:
Rating voltage: 300/500 VTest voltage: 3000 V
Minimum bending radius: 6 x cable diameter
Temperature range:
Fixed min/max: -40ºC to +70ºC (-40ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Radiation Best: 8 x 10 7 [/ sup] cJ / kg
Minimum bending radius: 6 x cable diameter
Oil resistance: Good
Flame resistance: IEC 332-1Approvals: Meets Swedish and European standards asSS EN 60204
- Number of cores:
- 2-25 .
- Material core insulation:
- Other
- Specification core insulation:
- Other
- Core identification:
- Numbers
- Protective conductor:
- Yes, No
- Material outer sheath:
- Other
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 70 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 500 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Grey
- Material insulation:
- TPE
- Core colour:
- Several
- Conductor surface:
- Bare
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 21.2-56 mm
- Reaction-to-fire according to EN 13501-6: Class:
- Dca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3 GKW, multi conductor
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX GKW P / GKW HP (polyolefin copolymer)
Conductor color: White, numbered. Transparent plastic foil
Conductor insulation outer sheath: RADOX GKW S (polyolefin copolymer)
Sheath color: Black
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals, flame resistance
BS 6853
DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-8 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin, None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 44.7-106.08 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTO B - Multi conductor Tinned
Shielded power cable for use in hybrid and electric vehicles (FHLR91XC13X & FHLR4GC13X)
Excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in trucks, among other things.
CAUTION: Special care must be taken for cables used with voltages above 60VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Tinned copper according to ISO C flexible 6
Conductor insulation: 155 (polyolefin)
Coat color: Orange
Technical data
Operating voltage: 1000VAC 1500VDC
Test voltage: 50HZ, 1MIN 3500 kV AC
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 4 x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 2 .
- Colour outer sheath:
- Orange
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Orange
- Halogen free:
- Yes
EN-Cable, multi conductor
Halogenfria, elektronstråle-tvärlänkade kablar med förbättrat beteende vid brand, lätt att skala, lödkolvbeständig och flexibel. Uppfyll kraven EN 50264-3-2
Kablarna är avsedda för permanent installation i rälsfordon eller för applikationer där en begränsad växelvis böjspänning uppstår under drift. Riktlinjer för val och installation beskrivs i standarderna EN 50355 och EN 50343.
RADOX EN 50264- 3- 2 ,EN 50306-4600V MM Flerledarkablar med reducerade väggmått
Nominell spänning: 600 / 1000 V AC
Risknivå: MM (extra låg temperatur, extra olja och extra bränslebeständig)
- Number of cores:
- 2-3 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-125 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 125 °C
- Screen:
- No
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 24.9-26.7 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX 3 GKW/S EMC
Halogenfri styrkabel för skyddad fast förläggning i tågapplikationer. Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen.
Användningsområden är styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Tålig mot hög mekanisk belastning, olja och bränsle.
- Number of cores:
- 3-8 .
- Material core insulation:
- Polyolefin
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- Yes, No
- Material outer sheath:
- Polyolefin
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black, Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -40-120 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 120 °C
- Screen:
- Yes, No
- Armouring/reinforcement:
- Braiding, None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 600 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Min. permitted bending radius, stationary application/permanent installation:
- 48.6-240.24 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
RADOX AUTO B - Multi conductor red Tinned
Shielded power cable for use in hybrid and electric vehicles (FHLR91XC13X & FHLR4GC13X)
Excellent resistance to high and low temperature, ozone and weather resistance, resistant to high pressure temperature, engine oil, fuels and hydrolysis, flame retardant, high abrasion resistant, solder resistant, easy to strip and process, according to ISO 6722 class D, LV 112, ISO 14572, LV 212, DIN 76722.
Complies with EU Directive 2000/53 / EC on end-of-life vehicles. It is free of lead, mercury, cadmium and chromium VI.
Use:
Low voltage cable, for use in trucks, among other things.
CAUTION: Special care must be taken for cables used with voltages above 60 VDC to protect them from mechanical stress to avoid shocks (ISO 6722: 2006)
Conductor: Annealed copper according to ISO C flexible 6
Conductor insulation: 155 (polyolefin)
Coat color: Orange
Technical data:
Operating voltage: 1000VAC 1500VDC
Test voltage: 50HZ, 1MIN 3500 kV AC
Temp. range: -40ºC to + 150ºC (3000H)
Minimum bending radius: 4x the diameter of the cable
Approvals, Standards:
ISO 6722 class D iSO 19642-9
- Number of cores:
- 3 .
- Colour outer sheath:
- Orange
- Nominal voltage:
- 1000 V
- Single insulated/Double insulated:
- Double insulated
- Colour:
- Orange
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
RADOX 4 GKW-AX/S 1800/3000 V - multi conductor
Halogenfri skärmad dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Skärm: Förtent kopparfläta. Täckningsgrad c:a 85%.
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
- Number of cores:
- 4 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 3000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Low smoke (according to EN 61034-2):
- Yes
RADOX GKW-LW - Multi conductor
Halogenfri styrkabel för skyddad fast förläggning i tågapplikationer.
Kabeln har väldigt liten ytterdiameter och används i trånga utrymmen. Användningsområden är styr- och apparatskåp, kontrollpaneler, signalkretsar och inre styrkabel i övrig tågutrustning. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW P/ GKW HP (polyolefin-copolymer)
Ledarfärg: Vita, numrerade Transparant plastfolie Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 600/1000 V AC, 750/1500 V DC
Provspänning: 3500 V (50 Hz, 5 min)
Temp. område: -40ºC till +120ºC
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100 IEC 60332-1
EN 50265-2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-12 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1500 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Low smoke (according to EN 61034-2):
- Yes
RADOX 125B Multi conductor screened
Halogenfri kabel lämpligt både för fast förläggning eller som anslutningskabel i torra, fuktiga och våta utrymmen både inom- och utomhus.
Med hänsyn av de goda mekaniska egenskaper samt den höga kemikaliebeständigheten, är RADOX 125 speciellt lämplig inom industrin i krävande miljöer, t.ex för maskiner och industriutrustningar. Kabeln har flätad kopparskärm med hög täckningsgrad, därför är den mycket lämplig i miljöer med hög störningsnivå (enligt EMC-direktivet).
- Number of cores:
- 2-12 .
- Protective conductor:
- No
- Material outer sheath:
- None
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Conductor material:
- Copper
- Screen:
- Yes
- Drain wire:
- No
- Nominal voltage:
- 1000 V
- Halogen free:
- Yes
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- Eca
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- Yes
RADOX TENUIS -TW 600V MM
Halogen-free control cable for protected fixed installation in train applications. The cable has a very small outer diameter and is used in tight spaces, smaller, lighter and more flexible than previous cables for railway application.
Areas of use are control and control cabinets, control panels, signal circuits and internal control cable in other train equipment. Guidelines for selection and installation are described in the standards EN 50355 and EN 50343. Resistant to high mechanical loads, oil and fuel.
Structure
Conductor: Tinned multi-wire copper according to IEC 60228 class 5
Conductor insulation inner jacket: RADOX EI 303 (polyolefin copolymer)
Conductor color: White, numbered and g = green / yellow. Transparent plastic foil
Conductor insulation outer sheath: RADOX EM 104 (polyolefin copolymer)
Sheath color: Black with yellow text
Technical data:
Operating voltage: 600/1000 V AC, 750/1500 V DC
Test voltage: 3500 V (50 Hz, 5 min)
Temp. range: -40ºC to + 120ºC
Minimum bending radius: 3 x cable diameter (see data sheet)
Approvals:
EN 50355 and EN 50343, flame resistance
BS 6853 DIN 5510
NF F16-101
BS 4066-3
BS 6583
BS 6853 cat. D
BS 6853 cat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1
EN 50265 -2-1 IEC 60332-3-24
EN 50266-2-4 IEC 60754-1
EN 50267-2-1 IEC 60754-2
EN 50267-2-3 IEC 61034-2
EN 50268-2
- Number of cores:
- 2-12 .
- Colour outer sheath:
- Black
- Nominal voltage:
- 1000 V
- Colour:
- Black
- Material insulation:
- Polyolefin (POE)
- Conductor surface:
- Tinned
- Halogen free: