Halogen-free cable suitable both for fixed installation or as a connection cable in dry, damp and wet areas both indoors and outdoors.
Due to the good mechanical properties and the high chemical resistance, RADOX 125 is especially suitable in industry in demanding environments, eg for machines and industrial equipment.
Number of cores:
2-27 .
Protective conductor:
No
Material outer sheath:
None
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Screen:
No
Armouring/reinforcement:
None
Drain wire:
No
Nominal voltage:
1000 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Conductor surface:
Tinned
Halogen free:
Yes
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
Halogen-free cable suitable both for fixed installation or as a connection cable in dry, damp and wet areas both indoors and outdoors.
Due to the good mechanical properties and the high chemical resistance, RADOX 125 is especially suitable in industry in demanding environments, eg for machines and industrial equipment.
Number of cores:
4-16 .
Protective conductor:
No
Material outer sheath:
None
Colour outer sheath:
Black
Flame retardant:
According to IEC/EN 60332-1-2
Conductor material:
Copper
Screen:
No
Drain wire:
No
Nominal voltage:
1000 V
Halogen free:
Yes
Conductor category:
Class 5 = flexible
Colour:
Black
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Conductor surface:
Tinned
Halogen free:
Yes
Reaction-to-fire according to EN 13501-6: Class:
Eca
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
Crimping coaxial for Huber & Suhner coaxial connectors.
22544754: Small tool without dies
22544755: Small tool incl. 3 sets of dies (1/2A, 2B, 2C)
Dies:
1/2A: 76 Z-0-2-51, square 0.7/1.6 mm, hexagon 3.3 mm
2B: 76 Z-0-3-51, square 1.6 mm, hexagon 5.5 mm
2C: 76 Z-0-4-51, square 1.6 mm, hexagon 6.5 mm
Flexibel kopplingskabel för intern kabeldragning i lampor, uppvärmningsanordningar, elektriska maskiner, styr- och apparatskåp, samt inom byggnadsindustrin. Idealisk för installation inuti rör samt för utanpåliggande installation.
Mycket goda elektriska och mekaniska egenskaper. Brett temperaturområde samt hög tålighet mot oljor, ozon, hydrolys och mekanisk påverkan. Kopplingstråden är svårantändlig, vid brand utvecklas minimalt med rök och inga korrosiva gaser avges.
Number of cores:
1 .
Material core insulation:
Polyolefin
Specification core insulation:
Other
Core identification:
None
Protective conductor:
No
Material outer sheath:
None
Specification material outer sheath:
Other
Colour outer sheath:
Blue, Brown, Yellow, Grey, Orange, Red, Black, White, Other
Flame retardant:
According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration:
-40-125 °C
Conductor material:
Copper
Twisted cores:
No
Max. conductor temperature:
125 °C
Screen:
No
Protective barrier:
N/A
Armouring/reinforcement:
None
Insulation integrity:
N/A
Drain wire:
No
Nominal voltage:
600 V
Conductor category:
Class 5 = flexible
Colour:
Black, Grey, Orange, Yellow, Green/yellow, Brown, Red, White, Blue
Material insulation:
Polyolefin (POE)
Operating temperature:
-40-125 °C
Core colour:
Blue, Brown, Grey, Green/yellow, Red, Black, White
Conductor surface:
Tinned
Halogen free:
No
Packaging:
Drum, Spool HS400, Spool HS401
Min. permitted bending radius, stationary application/permanent installation:
7.8-33.3 mm
Reaction-to-fire according to EN 13501-6: Class:
N/A
Reaction-to-fire according to EN 13501-6: Smoke production:
N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
N/A
Reaction-to-fire according to EN 13501-6: Acidity:
N/A
Low smoke (according to EN 61034-2):
Yes
Low temperature resistant (according to EN 60811-504+505+506):
Halogenfri dubbelisolerad kopplingskabel för fast förläggning i tågapplikationer både inom- och utomhus.
Lämplig i styr- och apparatskåp, konverterare och kontrollpaneler. Tålig mot hög mekanisk belastning, olja och bränsle.
Uppbyggnad:
Ledare: Förtent flertrådig koppar enligt IEC 60228 klass 5
Ledarisolation innermantel: RADOX GKW K (polyolefin-copolymer)
Ledarisolation yttermantel: RADOX GKW S (polyolefin-copolymer)
Mantelfärg: Svart
Tekniska data:
Driftspänning: 1.8/3.0 kV AC, 2.25/4.5 kV DC
Provspänning: 6500 V (50 Hz, 15 min)
Temp. område: -40º C till +120º C
Minsta böjradie: 3 x kabelns diameter (se datablad)
Godkännanden, flambeständighet
BS 6853
DIN 5510
NF F16-101
BS 4066-3, BS 6583
BS 6853 kat. D
BS 6853 kat. B
DIN EN 50265-2-1
DIN EN 50266-2-4
DIN EN 50266-2-5
DIN EN 50268-2
NF C32-070 TEST 2
NF X10-702-2
NF X70-100
IEC 60332-1, EN 50265-2-1
IEC 60332-3-24, EN 50266-2-4
IEC 60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2