Logged in as:

360 view

12515492-100

RADOX 125, 0.75mm2, GREEN SPOOL HS150, 600V, HF, FT, 125C

Sku

12515492-100

Availability:
Yes
  • Total: 1
Product Description
RADOX 125 - Spool
  • Total: 1
  • Total: 1

Related items

RADOX 125 - Spool

  • Total: 1
Number of cores 1 .
Material core insulation Polyolefin
Specification core insulation Other
Core identification None
Protective conductor No
Material outer sheath None
Specification material outer sheath Other
Colour outer sheath Green
Flame retardant According to IEC/EN 60332-1-2
Permitted cable outer temperature after assembling without vibration -55-145 °C
Conductor material Copper
Twisted cores No
Max. conductor temperature 125 °C
Screen No
Protective barrier N/A
Armouring/reinforcement None
Insulation integrity N/A
Drain wire No
Nominal voltage 600 V
Halogen free Yes
Conductor category Class 5 = flexible
Single insulated/Double insulated Single insulated
Colour Green
Material insulation Polyolefin (POE)
Operating temperature -40-125 °C
Core colour Green
Conductor surface Tinned
Packaging Spool HS150
Min. permitted bending radius, stationary application/permanent installation 6.75 mm
Nominal cross section conductor 0.75 mm²
MOQ 100 .
Outer diameter approx. 2.25 mm
Min. permitted bending radius, stationary application/permanent installation 6.75 mm
Unit m
Nominal voltage 600 V
Barcode 761183201567
Country of origin CH
Item status Non Stock Item, can be on stock but is not a regular stock item.
MOQ 100 .
Packaging Spool HS150
Stock code 12515492-100
Taric code 85444991
Unit m
Approved according to EN 50267-2-1 Yes
Approved according to EN 50267-2-3 Yes
Approved according to EN 50268-2 Yes
Approved according to IEC 60754-1 Yes
Approved according to IEC 60754-2 Yes
Reaction-to-fire according to EN 13501-6: Class Eca
Reaction-to-fire according to EN 13501-6: Smoke production N/A
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles N/A
Reaction-to-fire according to EN 13501-6: Acidity N/A
Halogen free Yes
Low smoke (according to EN 61034-2) Yes
Low temperature resistant (according to EN 60811-504+505+506) No
Oil resistant according to EN IEC 60811-404 No
Flame retardant According to IEC/EN 60332-1-2
ETIM-Class EC003248 - Power cable < 1 kV, for permanent installation
ETIM-Release 9.0
Trademark Huber+Suhner
Product Group RXL 125, Single conductor, Tinned
Search Description RXL 125
Alternative SKU 12515492-100
CA Proposition 65 No CA Prop65
Conflict Minerals Yes, see report under tab "Documents"
General compliance statement from manufacturer https://www.nelco.se/Image/GetDocument/1184
PFAS No PFAS
REACH No SVHC (240 Subs. 23 Jan 2024)
RoHS RoHS 3 (2015/863)
SCIP Not Applicable
US TSCA No (5 PBT Subs, Feb 2021)

Genererate statement of compliance:

Generate Datasheet:

We are using Cookies to give you a superior user experience. If you want to find out more about cookies and how we use them, please go to our cookie page. Further browsing of this site indicates that you accept our cookie policy.