H01N2-D FT - Drum
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Packaging: Drum
Structure:
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical data
Rating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF)Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
Technical properties
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 66 mm, 76.2 mm, 85.2 mm, 99 mm, 115.2 mm
Show more
Item List
- Total: 16
- Total: 16
Accessories
Related products
Spare Parts
Product video
Documents
Manuals, Datasheets, Sketches & Drawings
Dimensions
- Total: 16
- Total: 16
Similar Options
Approvals
- Total: 16
Product Description | Reaction-to-fire according to EN 13501-6: Class | Reaction-to-fire according to EN 13501-6: Smoke production | Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | Reaction-to-fire according to EN 13501-6: Acidity | Halogen free | Low smoke (according to EN 61034-2) | Low temperature resistant (according to EN 60811-504+505+506) | Oil resistant according to EN IEC 60811-404 | Flame retardant | Approved according to CE | Availability | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
H01N2-D, WELDING CABLE, 25mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
H01N2-D, WELDING CABLE, 10mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 16mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 16mm2, RED DRUM, 100V, NEOPREN, FT, 80C |
|
No
|
|
|
|||||||||
H01N2-D, WELDING CABLE, 25mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
H01N2-D, WELDING CABLE, 25mm2, RED DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, RED DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 50mm2, RED DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 70mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 70mm2, RED DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
No
|
|
|
H01N2-D, WELDING CABLE, 95mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
H01N2-D, WELDING CABLE, 95mm2, RED DRUM, 100V, NEOPREN, FT, 80C | N/A | N/A | N/A | N/A | No | No | No | No | According to IEC/EN 60332-1-2 |
|
Yes
|
|
|
- Total: 16
Technical Properties
- Total: 16
Product Description | Number of cores | Material core insulation | Specification core insulation | Core identification | Protective conductor | Material outer sheath | Specification material outer sheath | Colour outer sheath | Flame retardant | Permitted cable outer temperature after assembling without vibration | Conductor material | Twisted cores | Max. conductor temperature | Screen | Protective barrier | Armouring/reinforcement | Insulation integrity | Drain wire | Halogen free | Conductor category | Single insulated/Double insulated | Core colour | Conductor surface | Min. permitted bending radius, stationary application/permanent installation | Availability | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
H01N2-D, WELDING CABLE, 25mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 76.2 mm |
Yes
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 85.2 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 99 mm |
Yes
|
|
|
H01N2-D, WELDING CABLE, 10mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | Copper | No | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned |
No
|
|
|
|||
H01N2-D, WELDING CABLE, 16mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 66 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 16mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | -20-80 °C | 80 °C | Class 6 = very flexible | Single insulated | 66 mm |
No
|
|
|
||||||||||||||||||
H01N2-D, WELDING CABLE, 25mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 76.2 mm |
Yes
|
|
|
H01N2-D, WELDING CABLE, 25mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Red | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Red | Tinned | 76.2 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 85.2 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Red | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Red | Tinned | 85.2 mm |
Yes
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 99 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 50mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Red | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Red | Tinned | 99 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 70mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned | 115.2 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 70mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Red | According to IEC/EN 60332-1-2 | -20-80 °C | Copper | No | 80 °C | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Red | Tinned | 115.2 mm |
No
|
|
|
H01N2-D, WELDING CABLE, 95mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Black | According to IEC/EN 60332-1-2 | Copper | No | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Black | Tinned |
Yes
|
|
|
|||
H01N2-D, WELDING CABLE, 95mm2, RED DRUM, 100V, NEOPREN, FT, 80C | 1 . | Rubber | Other | None | No | None | Other | Red | According to IEC/EN 60332-1-2 | Copper | No | No | N/A | None | N/A | No | No | Class 6 = very flexible | Single insulated | Red | Tinned |
Yes
|
|
|
- Total: 16
Other information
- Total: 16
Product Description | ETIM-Class | ETIM-Release | Trademark | Product Group | Search Description | Alternative SKU | Availability | ||
---|---|---|---|---|---|---|---|---|---|
H01N2-D, WELDING CABLE, 25mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013025FT-100P5 |
Yes
|
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013035FT-100P5 |
No
|
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK 100m/P5 DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013050FT-100P5 |
Yes
|
|
|
|
H01N2-D, WELDING CABLE, 10mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 10MM2, SVART | 013010FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 16mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013016FT-500 |
No
|
|
|
|
H01N2-D, WELDING CABLE, 16mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 16MM2, RÖD | 013016-7FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 25mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013025FT-500 |
Yes
|
|
|
|
H01N2-D, WELDING CABLE, 25mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 25MM2, RÖD | 013025-7FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 35MM2, SVART | 013035FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 35mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 35MM2, RÖD | 013035-7FT-500 |
Yes
|
|
|
H01N2-D, WELDING CABLE, 50mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013050FT-500 |
No
|
|
|
|
H01N2-D, WELDING CABLE, 50mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 50MM2, RÖD | 013050-7FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 70mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | 013070FT-500 |
No
|
|
|
|
H01N2-D, WELDING CABLE, 70mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 70MM2, RÖD | 013070-7FT-500 |
No
|
|
|
H01N2-D, WELDING CABLE, 95mm2, BLACK DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 95MM2, SVART | 013095FT-500 |
Yes
|
|
|
H01N2-D, WELDING CABLE, 95mm2, RED DRUM, 100V, NEOPREN, FT, 80C | EC003248 - Power cable < 1 kV, for permanent installation | 9.0 |
|
Cable - H01N2-D, Tinned | H01N2-D, SVETSKABEL, 95MM2, RÖD | 013095-7FT-500 |
Yes
|
|
|
- Total: 16
Back to top