Begin filter on Product Category and then Product Group. The list result will then be refined and relevant filter options will be displayed.
Refined by
Hide irrelevant options
Nominal cross section conductor
Core colour
Colour outer sheath
Outer diameter approx.
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Show all filters
Hide all filters
List result: 013070 FT
- Total: 8
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
Yes
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Core colour:
- Red
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Spool
H01N2_D_FT_Trumma 25m_vp
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Structure
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical dataRating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF) Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 58.2-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
H01N2-D FT - Drum
H01N2_D_FT_Trumma_500m_vp
Oil and weather resistant connection and welding cable. For use where the mechanical stresses are high, in both dry and wet conditions, indoors and outdoors.
Packaging: Drum
Structure:
Conductors: Extra-wide and fine wire tinned copper
Conductor Insulation: Rubber (Neoprene)Sheath
Colour: Black
Packaging: Spool, coil or drum
Technical data
Rating voltage: 100V
Test voltage: 1000V
Temperature range: Fixed min/max: -40ºC to +80ºC (-40ºF to +176ºF)Moving min/max: -25ºC to +80ºC (-13ºF to +176ºF)
Minimum bend radius: 5 x cable diameter
Approvals: CE
- Number of cores:
- 1 .
- Material core insulation:
- Rubber
- Specification core insulation:
- Other
- Core identification:
- None
- Protective conductor:
- No
- Material outer sheath:
- None
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Red, Black
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -20-80 °C
- Conductor material:
- Copper
- Twisted cores:
- No
- Max. conductor temperature:
- 80 °C
- Screen:
- No
- Protective barrier:
- N/A
- Armouring/reinforcement:
- None
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 6 = very flexible
- Single insulated/Double insulated:
- Single insulated
- Core colour:
- Red, Black
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 66-115.2 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 8