Begin filter on Product Category and then Product Group. The list result will then be refined and relevant filter options will be displayed.
Refined by
Hide irrelevant options
Product Group
Colour
Nominal cross section conductor
Halogen free
Conductor Surface
Number of cores
Outer diameter approx.
Min. permitted bending radius, stationary application/permanent installation
Diameter conductor
Show all filters
Hide all filters
List result: 070168-1
- Total: 4
DEF-CY (Defense)
80011
Flexible signal cable with fine wire conductor structure, as in combination with PVC sheath it provides a very flexible cable with a small bending radius. The cable is fitted with a screen of tinned copper wire, which protects against mechanical stress and particular it isolates all electrical frequency as well inside and outside the cable (EMC Directive).
It is used for signal, measurement, control and tone-frequency transmission in electronics, computers and signal systems.
Structure Conductor: Tinned copper
Conductor insulation: PVC
Core identification: Acc. to def 61-12.
Screen: Tinned copper braid
Outer sheath: PVC
Sheath colour: Grey
Technical data:
Rating voltage: 300 V
Test voltage: 1000 V
Temperature range: Fixed min/max: -30ºC to +70ºC (-22ºF to +158ºF)
Moving min/max: -5ºC to +70ºC (+23ºF to +158ºF)
Minimum bending radius: 15 x cable diameter
Oil resistance: Good
Flame resistance: IEC 228
- Number of cores:
- 2-36 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black, Grey, White
- Material insulation:
- Polyvinyl chloride (PVC)
- Operating temperature:
- -30-70 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- Yes, No
- Min. permitted bending radius, stationary application/permanent installation:
- 19-60.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 18 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Nominal voltage:
- 300 V
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Colour:
- Black
- Material insulation:
- Polyvinyl chloride (PVC)
- Operating temperature:
- -30-70 °C
- Core colour:
- Several
- Conductor surface:
- Tinned
- Halogen free:
- No
- Min. permitted bending radius, stationary application/permanent installation:
- 60.5 mm
- Approved according to IEC 228:
- Yes
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 18 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Core colour:
- Several
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 60.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Availability:
-
No
- Number of cores:
- 18 .
- Material core insulation:
- Polyvinyl chloride (PVC)
- Specification core insulation:
- Other
- Core identification:
- Colour
- Protective conductor:
- No
- Material outer sheath:
- Polyvinyl chloride (PVC)
- Specification material outer sheath:
- Other
- Colour outer sheath:
- Other
- Flame retardant:
- According to IEC/EN 60332-1-2
- Permitted cable outer temperature after assembling without vibration:
- -30-70 °C
- Conductor material:
- Copper
- Twisted cores:
- Yes
- Max. conductor temperature:
- 70 °C
- Screen:
- Yes
- Protective barrier:
- N/A
- Armouring/reinforcement:
- Braiding
- Insulation integrity:
- N/A
- Drain wire:
- No
- Halogen free:
- No
- Conductor category:
- Class 5 = flexible
- Core colour:
- Several
- Conductor surface:
- Tinned
- Min. permitted bending radius, stationary application/permanent installation:
- 60.5 mm
- Reaction-to-fire according to EN 13501-6: Class:
- N/A
- Reaction-to-fire according to EN 13501-6: Smoke production:
- N/A
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles:
- N/A
- Reaction-to-fire according to EN 13501-6: Acidity:
- N/A
- Low smoke (according to EN 61034-2):
- No
- Low temperature resistant (according to EN 60811-504+505+506):
- No
- Oil resistant according to EN IEC 60811-404:
- No
- Total: 4